Datenblatt-pdf.com


FS-N10 Schematic ( PDF Datasheet ) - Keyence

Teilenummer FS-N10
Beschreibung Digital Fiber Sensor Instruction Manual
Hersteller Keyence
Logo Keyence Logo 




Gesamt 6 Seiten
FS-N10 Datasheet, Funktion
Digital Fiber Sensor
FS-N10 Series
Instruction Manual
96M00603
Danger
Failure to follow these instructions may lead to death or seri-
ous injury.
Warning
Caution
Failure to follow these instructions may lead to injury.
Failure to follow these instructions may lead to product dam-
age (product malfunction, etc.)
Note Provides additional information on proper operations that can be easily mistaken.
Note
This provides tips about situations in which the feature being described is useful.
Tip
See "FS-N10 Series User's Manual" for details on the features of the FS-N10 series and
detailed instructions for configuration.
Hints on Correct Use
Warning
This product is used to detect targets. Do not apply the
product to safety circuits for human protection.
This product is not of explosion-proof construction. Do not
use the products in places with flammable gas, liquid, or
dust.
This product is a sensor of DC power supply type. Do not
apply AC power. The product may explode or burn if an AC
voltage is applied.
Do not wire the amplifier line along with power lines or high-tension lines, otherwise the sen-
sor may malfunction or receive damage due to noise.
When using a commercially available switching regulator, ground the frame ground terminal
and ground terminal.
Do not use the FS series outdoors, or in a place where extraneous light can enter the light-
receiving surface directly.
Due to the individual dispersion of characteristics and the difference in fiber unit model, the
maximum sensing distance or displayed value of all the units are not the same.
If the sensor is used in S-APC mode for a long time, the LED indicators will be imposed with
a heavy load. In that case, the sensor will be automatically set to ACC mode where the cur-
rent consumption of the sensor for light emission will be constant, and “END APC” will be
displayed. The sensor can be continuously used in this case. Replace the sensor, however, if
highly precise detection is required.
„ About UL Certification
The FS-N series is UL and C-UL certified, and is compliant with the UL and CSA standards.
Applicable standards UL508 Industrial Control Equipment
CAN/CSA C22.2 No.14-M05 Industrial Control Equipment
UL File No. E301717
UL categories: NRKH, NRKH7
Enclosure Type 1 (based on UL50 standard)
„ Notes on UL Certification
The power source used with the FS-N series must be UL Listing certified for Class 2 output
as stipulated by US National Electric Code (NEC) NFPA70.
Connect the FS-N12 and N14 to the FS-N11 and N13 main units for use.
Included accessories
Instruction Manual 1pc.
Fiber cutter
1pc.
FS-N10 Series Quick Start and Cabling
„ Quick Start
Fine sensitivity adjustment
Up Down
Output switch
Press the [MODE] button once, then
use to select L-on or D-on
Setting value Light intensity
Sensitivity setting
Preset function
Configure easily
with a single press
when receiving light
Power select switch *1
Press once each for workpiece/no workpiece
Standard MEGA (fixed)
*1 This is a channel switch on 2-output types.
*2 Press and hold the [MODE] button to make advanced settings.
„ Cabling
Note See page 4 for information about connecting to external devices other than the FS-
N11N.
Mounting Unit
Brown
DC12-24V
Black
Load
Blue
0V
„ Mounting on a DIN Rail
1 Align the claw at the bottom of the main body with
the DIN rail, as shown in figure1.
While pushing the main body in the direction of
the arrow 1, slant it in the direction of the arrow 2.
2 To dismount the sensor, raise the main body in
the direction of the arrow 3 while pushing the
main body in the direction of the arrow 1.
3
2
„ Installation on a Wall (Main Unit Only)
1 Attach the unit to the optional mounting bracket (OP-
73880), mount them together, and secure them with
two M3 screws as shown in figure2.
1
figure1
Connecting Fiber Unit
OP-73880
figure2
1 Open the dust cover in the direction shown by
arrow 1.
2 Move down the fiber lock lever in the direction
shown by arrow 2.
3 Insert a fiber unit into the fiber insertion holes
to a length of the fiber insertion sign (i.e.,
approximately 14 mm).
4 Move down the fiber lock lever in the direction
shown by arrow 4.
4
2
3
1
Fiber insertion sign
Note
If a thin fiber unit is used, an adapter provided with the thin fiber unit will be
required.
Unless the correct adapter is connected, the thin fiber unit will not detect
targets correctly (the adapter is supplied with the fiber unit).
Cable outer dia
1.3
Adapter
Adapter A
(OP-26500)
Appearance
Adapter B
1.0 (OP-26501)
To connect the coaxial reflective type fiber unit to the amplifier, connect the
single-core fiber to the transmitter side, and connect the multiple-core fiber
to the receiver side.
Single-core fiber
Multi-core fiber
Transmitter
Receiver
1






FS-N10 Datasheet, Funktion
Specifications
Type
Standard 1 output
Monitor
output
High functionality 2 output
Cable/M8 connector
Cable
M8 connector*1
e-CON connector*1
Cable
Cable
M8 connector*1
Main unit/sub unit
Main unit
Sub unit
(with output
cable)
Main unit
Sub unit
(with output
cable)
Main unit
Sub unit
(with output
cable)
Main unit
Main unit
Sub unit
(with output
cable)
Main unit
Sub unit
(with output
cable)
Model
NPN
FS-N11N FS-N12N FS-N11CN FS-N12CN FS-N11EN FS-N12EN FS-N11MN FS-N13N
FS-N14N
-
-
PNP
FS-N11P FS-N12P FS-N11CP FS-N12CP
-
-
-
FS-N13P
FS-N14P
FS-N13CP FS-N14CP
Control output
1 output
1 output
1 output
1 output
1 output
1 output
1 output
2 output
2 output
2 output
2 output
Monitor output (1-5 V)
-
-
-
-
-
- 1 output
-
-
-
-
External input
-
-
1 input
1 input
1 input
1 input
-
1 input
1 input
-
-
Response time
50 Ǵs (HIGH SPEED)/250 Ǵs (FINE)/500 Ǵs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA)
Control
output
NPN output
NPN open collector 30 V; 1 output max: 100 mA or less; 2 output total:
100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less
PNP output
PNP open collector 30 V; 1 output max: 100 mA or less; 2 output total:
100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less
Monitor output
1 to 5 V voltage output; load resistance 10 k: or more; repeat precision r 0.5% of F.S.; responsiveness 1 ms (FS-N11MN only)
External input
input time 2 ms (ON)/20 ms (OFF) or more
Multiple connections to sub
units
Up to 16 units can be connected total, but two-output type is treated as two units
Number of interference
prevention units
0 for HSP; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA (When set to double, the number of interference-prevention units will be doubled.)
Rating
Power voltage
12 - 24 V DC r 10% ripple (P-P) 10% or less
NPN
Normal:900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*2
Eco on mode:800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*2
Eco Full mode:470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)
PNP
Normal
Eco on mode
Eco Full mode
: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)*2
: 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V)*2
: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)
Normal
: 1050 mW or less(42 mA max. at 24 V,
56 mA max. at 12 V)*2
- Eco on mode : 950 mW or less(38 mA max. at 24 V,
47 mA max. at 12 V)*2
Eco Full mode
: 600 mW or less(24 mA max. at 24 V,
29 mA max. at 12 V)
Environme Operating
ntal ambient
resistance luminance
Incandescent lamp: 20,000 lx or less; Sunlight: 30,000 lx or less
Operating
ambient
temperature
-10 to +55 qC (no freezing)*3
Operating
ambient
humidity
35 to 85% RH (no condensation)
Vibration
resistance
10 to 55 Hz Compound amplitude 1.5 mm, 2 hours for each of X,Y,Z axis
Shock
resistance
500 m/s2 3 times for each of X,Y,Z axis
Case material
Both main unit and housing material: Polycarbonate
Weight
Approx 75g Approx 45g Approx 22g Approx 22g Approx 22g Approx 22g Approx 75g Approx 80g Approx 70g Approx 22g Approx 22g
*1 Use a cable length of 30m or less for M8 connector and e-CON connector types.
*2 Increases 100 mW (4.0 mA) for High Speed mode
*3 One or two more units connected: -10 to +55 qC; 3 to 10 more units connected: -10 to +50qC; 11 to 16 more units connected: -10 to +45qC. When using 2-outputs, one unit is counted as two units.
All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
Warranties and Disclaimers
KEYENCE, at its sole option, will refund, repair or replace at no charge any defective Products
within 1 year from the date of shipment. Unless stated otherwise herein, the Products should
not be used internally in humans, for human transportation, as safety devices or fail-safe sys-
tems. EXCEPT FOR THE FOREGOING, ALL EXPRESS, IMPLIED AND STATUTORY WAR-
RANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE AND NONINFRINGEMENT OF PROPRIETARY RIGHTS, ARE
EXPRESSLY DISCLAIMED. KEYENCE SHALL NOT BE LIABLE FOR ANY DIRECT, INDI-
RECT, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES, EVEN IF DAMAGES
RESULT FROM THE USE OF THE PRODUCTS IN ACCORDANCE WITH ANY SUGGES-
TIONS OR INFORMATION PROVIDED BY KEYENCE. In some jurisdictions, some of the fore-
going warranty disclaimers or damage limitations may not apply.
KEYENCE CORPORATION
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku,
Osaka, 533-8555, Japan
PHONE: +81-6-6379-2211
www.keyence.com
AUSTRIA
Phone: +43-2236-378266-0
BELGIUM
Phone: +32 2 716 40 63
CANADA
Phone: +1-905-696-9970
CHINA
Phone: +86-21-68757500
CZECH REPUBLIC
Phone: +420 222 191 483
FRANCE
Phone: +33 1 56 37 78 00
GERMANY
Phone: +49-6102-36 89-0
HONG KONG
Phone: +852-3104-1010
HUNGARY
Phone: +36 14 748 313
ITALY
Phone: +39-2-6688220
JAPAN
Phone: +81-6-6379-2211
KOREA
Phone: +82-31-642-1270
MALAYSIA
Phone: +60-3-2092-2211
MEXICO
Phone: +52-81-8220-7900
NETHERLANDS
Phone: +31 40 20 66 100
POLAND
Phone: +48 71 36861 60
Specifications are subject to change without notice.
Copyright (c) 2009 KEYENCE CORPORATION. All rights reserved.
00603E 0079-1 96M00603 Printed in Japan
SINGAPORE
Phone: +65-6392-1011
SLOVAKIA
Phone: +421 2 5939 6461
SWITZERLAND
Phone: +41 43 455 77 30
TAIWAN
Phone: +886-2-2718-8700
THAILAND
Phone: +66-2-369-2777
UK & IRELAND
Phone: +44-1908-696900
USA
Phone: +1-201-930-0100
A6WW1-MAN-0059
6

6 Page







SeitenGesamt 6 Seiten
PDF Download[ FS-N10 Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
FS-N10Digital Fiber Sensor Instruction ManualKeyence
Keyence

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche