DataSheet.es    


PDF G22K7MCD8 Data sheet ( Hoja de datos )

Número de pieza G22K7MCD8
Descripción Medical Catheter micro-BetaCHIP Probe
Fabricantes BetaTHERM 
Logotipo BetaTHERM Logotipo



Hay una vista previa y un enlace de descarga de G22K7MCD8 (archivo pdf) en la parte inferior de esta página.


Total 1 Páginas

No Preview Available ! G22K7MCD8 Hoja de datos, Descripción, Manual

BetaTHERM Sensors
Photo
Medical Catheter micro-BetaCHIP Probe
Medical Catheter micro-BetaCHIP Probe:
Applications
¥ Thermodilution catheters and other medical
applications.
¥ General Medical applications.
Thermistor Configuration
Custom lengths
3.18mm Nominal
(0.125")
Custom Lengths
1.5 Meter Typ.
3.18mm
(0.125")
0.457mm Dia. Typ.
(0.018")
38 AWG Solid Nickel
Epoxy Filled Polyimide
with Isomid Insulation
Tube (0.001" wall thickness)
Sample Part Number:
G 22K 7 MCD 8
Factory Assigned Number
micro-Chip Probe
Material Curve #
Resistance Value
@
25oC
Glass Coated Element
Features:
¥ Rapid Time Constant (200 milliseconds in liquids).
¥ Custom tolerances available.
¥ 0.3 mW/oC typ. Dissipation Constant in air at 25oC.
¥ Smaller than the mini-BetaCURVE device.
¥ Custom designs available.
The Medical Catheter micro-BetaCHIP probe is
packaged similar to the standard micro-BetaCHIP Probe
except that the thermistor element is a glass coated
thermistor of specific resistance value. The glass coated
thermistor adds extra moisture protection to the probe
design.
The probe is produced for Medical applications
which require rapid temperature response and very small
size. When used in thermodilution catheters, the thermistor
measures blood flow characteristics in the human body.
Supplied with custom lead lengths near 1.5 meters on small
reels (spools) with calibration data at 37oC. The standard
thermistor is denoted as G22K7MCD8. Many other custom
versions have been produced by BetaTHERM to meet
customers specific design criteria.
Medical Catheter micro-BetaCHIP Probe Part Number and Specifications:
Part Number
Resistance @
25 oC (ohms)
Resistance (ohms) and
Tolerance @ 37 oC
Alpha
@ 25 oC
0/50 oC Beta Curve #
Value
G22K7MCD8
22000
14004 +/- 15%
-3.87%
3422
7
BETA ApS (DK + NO): Phone: +45 59 31 11 88, Fax: +45 59 31 12 10, email: [email protected]
BEATA Komponent AB (SE): Phone: +46 (0)392 360 40, Fax: +46 (0)392 360 41, e-mail: [email protected]
16 BETA Finland OY (FI): Phone: +358 (0)9 260 9209, Fax: +358 (0)9 260 9208, e-mai: [email protected]
url: www.beta.dk, www.beata.se, www.betafinland.fi, www.betatherm.com

1 page





PáginasTotal 1 Páginas
PDF Descargar[ Datasheet G22K7MCD8.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
G22K7MCD8Medical Catheter micro-BetaCHIP ProbeBetaTHERM
BetaTHERM

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar