IS1000E-404 Datasheet, Funktion
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.
Mechanical Style Pressure Switch
Series IS1000
Long service life:
5 million cycles
IS1000-01 IS1000-01-X202
Specifications
Model
Fluid
Proof pressure
Max. operating pressure
Regulating pressure range (at OFF point)
Hysteresis
Error of scale
Repeatability
Contacts
Wiring specifications
Fluid
Ambient and fluid temperature
Port size
Weight
Switch Characteristics
IS1000-01
Air/Inert gas
1.0 MPa
0.7 MPa
0.1 to 0.4 MPa
0.08 MPa or less
±0.05 MPa
±0.05 MPa
1a
Grommet, Lead wire length 0.5 m (Standard)
Air
–5 to 60°C (No freezing)
R 1/8
74 g
ZSE„
ISE„
PSE
ZI SE3
PS
ZI SE12
ZSP
ISA2
IS„
ZSM
PF2„
IF„
Max. contact capacity
Voltage
Max. operating current
Impact resistance
Electrical Circuit
Up to 100 VAC/DC
AC 2 VA, 2 W DC
24 VAC/DC or less 48 VAC/DC
50 mA
40 mA
30 G
100 VAC/DC
20 mA
Data
Operating Pressure Range
ON pressure
0.5
OFF pressure
0.4
0.3
0.2
0.1
0
How to Order
0.1 0.2 0.3 0.4
Set pressure scale (MPa)
IS1000 01 S
Port size
01
N01
R 1/8
NPT 1/8
Seal
Nil None
S With seal
Option
X201
Lead wire length 3 m
X202 Regulating pressure range
0.1 to 0.6 MPa
X215
Lead wire length 3 m
Regulating pressure range
0.1 to 0.6 MPa
16-9-1






IS1000E-404 Datasheet, Funktion
ACAttachment Specifications Series
Pressure Switch with Piping Adapter (P)
Pressure switch with piping adapter
A
E
JIS symbol
D
23
Port size
Specifications
Fluid
Proof pressure
Maximum operating pressure
Set pressure range
(when OFF)
Differential
Ambient and fluid temperature
Switch characteristics
Contact point configuration
Maximum contact point capacity
Operating voltage: AC, DC
Max. operating current
Air
1.0MPa
0.7MPa
Center of
F.R.L. body
0.1 to 0.4MPa
0.08MPa
–5 to 60°C (with no freezing)
1a
2VA(AC), 2W(DC)
100V or less
12V to 24V AC, DC: 50mA
48V AC, DC: 40mA
100V AC, DC: 20mA
Model Note 1) Port size A B C D E Applicable model
IS1000E-2001 1/8
AC20
IS1000E-2002 1/4 30 68 57 28 16 AR20, AW20
IS1000E-2003 3/8
AWM20, AWD20
IS1000E-3002 1/4
AC25, AC30
IS1000E-3003 3/8 32 74.5 60.5 30 13 AR25, AR30, AW30
IS1000E-3004 1/2
AWM30, AWD30
IS1000E-4002 1/4
IS1000E-4003
IS1000E-4004
3/8
1/2
32
80.5 62.5
37
12.5
AC40
Note 2)
AR40, AW40
IS1000E-4006 3/4
AWM40, AWD40
Note 1) „ in the model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Note 2) A pressure switch cannot be mounted on AC40„-06 and AW40„-06.
Separate interfaces are required for modular unit.
∗∗ The pressure switch on AC40„-06 and above and AW40„-06 can be
mounted by screwing IS1000-01 into the piping adapter E500-„06-X501 or
E600-„06-X501 to E600-„06 to 10-X501 (with top-face thread Rc 1/8).
Products with a premounted switch are available as a special order. Please
contact SMC regarding their availability.
How to Order
IS1000E 30
Pressure switch
with piping
adapter
Body size
20 For AC20
30 For AC25, AC30
40 For AC40-02 to 04
Thread type
Nil Rc
N NPT
FG
03
Option
X201
X202
X207
X215
X250
X251
Lead wire length: 3m
Regulating pressure range: 0.1 to 0.6MPa
MPa/PSI Dual scale
Lead wire length: 3m; Regulating pressure range: 0.1 to 0.6MPa
Opposite-side mounting (Left-side mounting type)
Lead wire length: 3m; Opposite-side mounting (Left-side mounting type)
X252
Set pressure range: 0.1 to 0.6MPa; Opposite-side mounting
(Left-side mounting type)
X253
Lead wire length: 3m; Regulating pressure range: 0.1 to 0.6MPa;
Opposite-side mounting (Left-side mounting type)
This product is for overseas use only according to the new Measurement Law.
(The SI unit type is provided for use in Japan.)
Piping adapter port size
Symbol Port
size
01 1/8
02 1/4
03 3/8
04 1/2
06 3/4
Body size
20 30 40
——
●●●
●●●
● ●
——
14

6 Page









IS1000E-404 pdf, datenblatt
SMC Product Conforming to Inter
SMC products complying with EN/ISO, CSA/UL standards are supporting
CE Mark
The CE mark indicates that machines and components meet essential requirements of all the EC Directives
applied.
It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and
components are exported to the member Nations of the EU.
Once “A manufacturer himself” declares a product to be safe by means of CE marking (declaration of
conformity by manufacturer), free distribution inside the member Nations of the EU is permissible.
í CE Mark
SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in
accordance with CETOP (European hydraulics and pneumatics committee) guide lines.
í As of February 1998, the following 18 countries will be obliged to conform to CE mark legislation
Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, Greece, Liechtenstein, Sweden, Spain, Denmark,
Germany, Norway, Finland, France, Belgium, Portugal, Luxembourg
í EC Directives and Pneumatic Components
• Machinery Directive
The Machinery Directive contains essential health and safety requirements for machinery, as applied to
industrial machines e.g. machine tools, injection molding machines and automatic machines. Pneumatic
equipment is not specified in Machinery Directive. However, the use of SMC products that are certified as
conforming to EN Standards, allows customers to simplify preparation work of the Technical Construction File
required for a Declaration of Conformity.
• Electromagnetic Compatibility (EMC) Directive
The EMC Directive specifies electromagnetic compatibility. Equipment which may generate electromagnetic
interference or whose function may be compromised by electromagnetic interference is required to be immune
to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).
• Low Voltage Directive
This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC
operating voltage, and require electrical safety measures to be introduced.
• Simple Pressure Vessels Directive
This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V)
exceed 50 bar/L. Such vessels require EC type examination and then CE marking.
16-14-6

12 Page





SeitenGesamt 15 Seiten
PDF Download[ IS1000E-404 Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
IS1000E-402Mechanical Style Pressure SwitchSMC
SMC
IS1000E-403Mechanical Style Pressure SwitchSMC
SMC
IS1000E-404Mechanical Style Pressure SwitchSMC
SMC
IS1000E-405Mechanical Style Pressure SwitchSMC
SMC
IS1000E-406Mechanical Style Pressure SwitchSMC
SMC

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche