Datenblatt-pdf.com


KX-TDA600CE Schematic ( PDF Datasheet ) - Panasonic

Teilenummer KX-TDA600CE
Beschreibung Hybrid IP-PBX Service Manual
Hersteller Panasonic
Logo Panasonic Logo 




Gesamt 30 Seiten
KX-TDA600CE Datasheet, Funktion
ORDER NO. KMS0510151CE
Hybrid IP-PBX
KX-TDA600CE
(for Europe)
IMPORTANT INFORMATION ABOUT LEAD FREE, (PbF), SOLDERING
If lead free solder was used in the manufacture of this product the printed circuit boards will be marked PbF.
Standard leaded, (Pb), solder can be used as usual on boards without the PbF mark.
When this mark does appear please read and follow the special instructions described in this manual on the use of PbF and how
it might be permissible to use Pb solder during service and repair work.
© 2005 Panasonic Communications Co., Ltd. All
rights reserved. Unauthorized copying and
distribution is a violation of law.






KX-TDA600CE Datasheet, Funktion
KX-TDA600CE
4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Control Bus
Communication Bus
Switching
Power Input
PSU-M
PSU-L
External Battery
Maximum Power Failure Tolerance
Memory Backup Duration
Dialling
Trunk
Extension
Mode Conversion
Ring Frequency
Trunk Loop Limit
Operating
Environment
Temperature
Humidity
Conference Call Trunk (per shelf)
Music on Hold (MOH)
Paging
Serial Interface Port
Extension Connection Cable
Internal
External
RS-232C
USB
Dimension
Basic Shelf
Weight (when fully mounted) Basic Shelf
Original bus (16 bit, 8 MHz,10 megabytes per second)
H.100 bus conformity (1024 time slot)
Distributed Switching
100 V AC to 130 V AC, 2.5 A/200 V AC to 240 V AC, 1.4 A, 50 Hz/60 Hz
100 V AC to 130 V AC, 5.1 A/200 V AC to 240 V AC, 2.55 A, 50 Hz/60 Hz
+36 V DC (+12 V DC x 3, recommended maximum current per shelf is 28 Ah or lower)
300 ms (without using backup battery)
7 years
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600 maximum
0 °C to 40 °C
10%to 90% (non-condensing)
From 10 x 3-party conference call to 4 x 8-party conference call
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Level Control: -15 dB to +6 dB in 3 dB steps
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
1 (max 115.2 kbps)
1
SLT 1 pair wire (T, R)
DPT
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
APT
2-pair wire (T, R, D1, D2)
PT-interface CS
1-pair wire (D1, D2)
DSS Consoles and Add-on Key Module
1-pair wire (D1, D2)
430 mm (W) x 415 mm (H) x 270 mm (D)
(17 1/5 in x 16 3/5 in x 10 4/5 in)
Under 16 kg (35.2 lb)
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit
Minimum Leakage Resistance
Maximum Number of Extension
Instruments per Line
Ring Voltage
Trunk Loop Limit
Hookswitch Flash/Recall Timing Range
BRI Cards Internal ISDN Mode
Door Opener Current Limit
External Relay Current Limit
External Sensor Current Limit
Paging Terminal Impedance
MOH (Music on Hold) Terminal Impedance
PT: KX-T7600 series DPT: 90 ; all other DPTs/APTs: 40
SLT: 600 including set
Doorphone: 20
CS: 130 ; PT-interface CS: 65
15000 maximum
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of 2 DPTs and an SLT
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
1600 maximum
24 ms to 2032 ms
Supply Voltage: 40 V
Power Supply (BRI4): 4.5 W per 1 line, 10 W per 4 lines
Power Supply (BRI8): 4.5 W per 1 line, 20 W per 8 lines
Power Supply Method: Phantom Power Supply
24 V DC/30 V AC, 1 A maximum
24 V DC/30 V AC, 1 A maximum
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. The Hybrid IP-PBX detects input from the sensor when the signal is under
100
600
10000
6

6 Page









KX-TDA600CE pdf, datenblatt
KX-TDA600CE
4.4.2. Maximum Terminal Equipment
The following number of items of terminal equipment can be supported by the Hybrid IP-PBX.
Terminal Equipment Type
Telephone
(using Digital XDP)
SLT
KX-T7600 series DPT
Other DPT
APT
IP-PT
DSS console
CS
PS (without an EMEC card)
PS (with an EMEC card)
Voice Processing System (VPS)*2
Doorphone
Door Opener
External Sensor
External Relay
Add-on Key Module
USB Module
Basic System
160
(240)*1
160
160
128
80
160
32
16
16
16
16
160
160
2-shelf System 3-shelf System
320
(480)*1
480
(720)*1
320 480
320 480
256 384
160 240
320 480
64
64 96
256
512
8
32 48
32 48
32 48
32 48
320 480
320 480
4-shelf System
640
(960)*1
640
640
512
320
640
128
64
64
64
64
640
640
*1 Even when Digital XDP is used, each shelf supports a maximum of 160 KX-T7600 series DPTs.
*2 Only a single VPS can be connected to one optional service card.
4.4.3. Power Supply Unit Selection for Each Shelf
The Hybrid IP-PBX needs a power supply unit (PSU) suitable for its configuration. For each shelf, calculate the load figure from
the type and number of items of equipment to be connected, and then determine the type of PSU that will be required.
Load Figure Calculation
PT
Extension Card *1
CS (1 unit)
PT-interface CS (1 unit)
ISDN Extension
VPS (1 port)
Equipment Type
KX-T7600 series DPT/KX-T7600
series DSS console
KX-T7560/KX-T7565 DPT
Other DPT/Other DSS console
APT
IP-PT
DHLC8
SLC8
ESLC16
EMSLC16
*1 Only the extension cards that can support SLTs count for the load figures.
Load Figure
1
1
4
4
0
8
8
16
16
4
4
2
1
PSU Capability
Each PSU supports a different load figure.
PSU-M
PSU-L
PSU Type
Maximum Load Figure
128
512
If the total load figure is greater than 128, you must install the PSU-L. If the total load figure is less than 128, but you expect
expansion in the future, it may be better to install the PSU-L instead of the PSU-M. There is no harm in installing a PSU that
is larger than is required for the current configuration.
12

12 Page





SeitenGesamt 30 Seiten
PDF Download[ KX-TDA600CE Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
KX-TDA600CEHybrid IP-PBX Service ManualPanasonic
Panasonic

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC