Datenblatt-pdf.com


G6BK-1114P-FD-US-U Schematic ( PDF Datasheet ) - Omron Electronics

Teilenummer G6BK-1114P-FD-US-U
Beschreibung PCB Power Relay
Hersteller Omron Electronics
Logo Omron Electronics Logo 




Gesamt 10 Seiten
G6BK-1114P-FD-US-U Datasheet, Funktion
G6B
PCB Power Relay
High Capacity and High
Dielectric Strength Miniature
Relay with Fully Sealed
Construction in 5 A (8 A)
SPST-NO (1a),
SPST-NC (1b),
DPST-NO (2a),
DPST-NC (2b) Types
• High sensitive with operating power of 98 mW.
(G6B-1114P-US and G6B-1174P-US models)
• High insulation with dielectric strength of 3,000VAC
between coil and contacts (impulse withstand voltage of
6 kV).
• Stick packing models are provided in consideration of compatibility to the automatic production line.
• Standard model conforms to UL/CSA standards. Other SEV approved models are also available.
• AgSnIn contacts suitable for loads that generate surge voltage (inductive load, capacity load, etc.) available. (-FD type)
• Ultrasonic cleanable models available. (-U type)
• Operation indicator & built-in surge absorption diode available. (-ND type)
• 2-Pole type available.
RoHS Compliant
Application Examples
• Ideal for output applications of control equipments
Model Number Legend
G6B-@-@@@@@-@-@-@-@-@
— ————— — — — — —
1 2 3 4 5 6 7 8 9 10 11
1. Relay Function
None: Single-side stable
U : Single-winding latching
(G6B@-1114 models only)
K : Double-winding latching
(G6B@-1114 models only)
2. Number of poles
1: 1-pole
2: 2-pole
3. Contact Form
1: SPST-NO (1a)
1: SPST-NO (1a)+SPST-NC (1b)
2: DPST-NO (2a)
0: DPST-NC (2b)
4. Classification
1: Standard
7: High-capacity
5. Enclosure rating
4: Fully sealed
7: Flux protection
6. Terminal Shape
P: PCB terminals
Socket mounting terminals
7. Contact material
None: Standard (Ag-alloy (Cd free))
FD : AgSnIn contact
(Suitable for DC inductive load with
high inrush current)
8. Operation Indicator Diode
Availability
None: Standard
ND : Operation indicator & coil surge
absorption diode
(for -1177 type only)
9. Approved Standards
US: UL/CSA
10. Washability
None: Standard
U : For ultrasonically cleanable
11. Mounting
None: Mounted directly to PCB
P6B : Mounted to Socket
G
6
B
http://www.Datasheet4U.com
1






G6BK-1114P-FD-US-U Datasheet, Funktion
G6B
PCB Power Relay
Shock Malfunction
Y
300
Energized
XZ
400
300
100
200
X
1,000
1,000Y
Energized
Z
1,000
600
X
1,000
Y
1,000
Reset
Set
Z
1,000
700
Z' 300
200
100
400
X'
300
Unit: m/s2
Y'
Sample: G6B-1114P-US
Number of Relays: 12 pcs
Test Conditions: Shock is applied in ±X, ±Y,
and ±Z directions three times each with without
energizing the Relays
Shock direction
to check the number of X
X'
malfunctions.
Y
Requirement: None
Z
malfuction 100 m/s2
Z'
Y' (Coil)
Hot Start
40 Sample: G6B-1114P-US
G6B-1174P-FD-US
G Number of Relays: 10 pcs
30 Test: the variation of operating voltage is measured
6 based on cold start at 23°C, during which rated
B voltage is applied to the coil with rated
20 contact current (5A), and left for 1
hour each under different
ambient
temperatures.
10
120% applied
110% applied
0 100% applied
10
1,000
Z'
1,000
X'
1,000
Y'
Unit: m/s2
Sample: G6B-1174P-US
G6B-1174P-FD-US
Test Conditions: Shock is applied in ±X, ±Y,
and ±Z directions three times each with without
energizing the Relays
Shock direction
to check the number of X
X'
malfunctions.
Y
Requirement: None
Z
malfuction 100 m/s2
Z'
Y' (Coil)
40
Sample: G6B-1174P-US
Test: the variation of operating voltage is measured
30
based on cold start at 23°C, during which rated
voltage is applied to the coil with rated contact
current (8A), and left for 1 hour
each under different ambient
20 temperatures.
120% applied
10
110% applied
100% applied
0
10
1,000
Z'
1,000
X'
1,000
Y'
Unit: m/s2
Sample: G6BK-1114P-US
Number of Relays: 12 pcs
Test Conditions: The value at which
malfunction occurred was measured after
applying shock to the
Shock direction
test piece 3 times each X
X'
in 6 directions along 3 Y
axes.
Z
Standard value:
Z'
300 m/s2
Y' (Coil)
40 Sample: G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
30 Test: the variation of operating voltage is
measured based on coil cold start at 23°C, during
which rated voltage is applied to the coil with rated
20 contact current (5A), and left
for 1 hour each under different
ambient temperatures.
10
120% applied
0 110% applied
100% applied
10
20
50 40 20 0
20 40
60 80 100
Ambient temperature (°C)
20
50 40 20 0
20 40 60 80 100
Ambient temperature (°C)
20
50 40 20 0
20 40 60 80 100
Ambient temperature (°C)
Dimensions
1-pole Single-side Stable Models
G6B-1114P(-FD)-US
10 max.
(9.8)* 0.3
3.5
0.85 0.9
20 max.
0.5 (19.9)*
10 max.
(9.8)*
0.9 0.5
* Average value
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
2.54
Four, 1.1-dia. holes
2.54
(1.2) 1
6
34
10.16
7.62
(1.1)
Note: Check carefully
the coil polarity of the
Relay.
Note: Orientation marks are indicated as follows:
1-pole Single-side Stable Models
G6B-1174P(-FD)-US
12.5 max.
(12.45)* 0.65
3.5
0.85 0.9
20.2 max.
0.45 (20.0)*
10 max.
(9.9)*
0.9 0.5
* Average value
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
2.54
Four, 1.1-dia. holes
2.54
(1.2) 1
6
34
10.16
7.62
(1.2)
Note: Check carefully
the coil polarity of the
Relay.
Note: Orientation marks are indicated as follows:
6

6 Page







SeitenGesamt 10 Seiten
PDF Download[ G6BK-1114P-FD-US-U Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
G6BK-1114P-FD-US-UPCB Power RelayOmron Electronics
Omron Electronics

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche