Datenblatt-pdf.com


1FT6062-1AH71 Schematic ( PDF Datasheet ) - Siemens

Teilenummer 1FT6062-1AH71
Beschreibung motors
Hersteller Siemens
Logo Siemens Logo 




Gesamt 30 Seiten
1FT6062-1AH71 Datasheet, Funktion
Synchronous motors
© Siemens AG 2008
1FT6 motors
I Overview
4
I Benefits
7 Optimum surface quality at the workpiece thanks to highest
smooth running characteristics degree of radial eccentricity
(sinusoidal current injection)
7 Minimized downtime due to high dynamic performance
7 Power and signal connections for use in highly contaminative
environments
7 High resistance to cantilever force
7 High thermal reserves for continuous or overload applications
7 High overload capability (250 ms)
7 Extremely high efficiency
7 Extremely good drive dynamic response due to low rotor
moments of inertia
7 Low torque ripple (mean value 1 %)
7 High degree of protection
I Applications
1FT6 motors are permanent-magnet synchronous motors with
compact dimensions.
• High-performance machine tools
• Machines with stringent requirements in terms of dynamic
response, precision and flexibility, e.g. packaging machines,
cross cutters, converting machines, material handling and
printing machines.
1FT6 motors with integrated encoders can be operated on the
SINAMICS drive system.
The fully digital control of the SINAMICS S120 drive system and
the encoder technology of the 1FT6 motors fulfill the highest de-
mands in terms of dynamic performance, speed setting range,
and rotational and positioning accuracy.
1FT6 motors are available with natural cooling, forced ventilation
or also with water cooling. With the natural cooling method, heat
is dissipated through the surface of the motor, whereas with the
forced ventilation method, heat is forced out by means of built-
on fans. Maximum power ratings, as well as a high degree of
protection, can be achieved using water cooling.
4/12
Siemens PM 21 · 2008
Free Datasheet http://www.Datasheet4U.com






1FT6062-1AH71 Datasheet, Funktion
© Siemens AG 2008
Synchronous motors
1FT6 motors, core type
Natural cooling
I Selection and ordering data
Motor type
(continued)
Static
current
Calculated
power
Pcalc 4)
I0 Pcalc
at M0
for M0
T=100 K T=100 K
∆∆
SINAMICS S120 Motor Module
Rated
Booksize format
output
current 3)
Irated
Order No.
Power cable with complete shield
Motor connection (and brake connection) via
power connector
Power
Cable
connector cross-
section 2)
Order No.
Pre-assembled cable
A kW (HP) A
Size
mm2
1FT6102-1AC7...
1FT6105-1AC7...
1FT6044-1AF7...
1FT6062-1AF7...
1FT6064-1AF7...
1FT6082-1AF7...
1FT6084-1AF7...
1FT6086-1AF7...
1FT6062-1AH7...
1FT6064-1AH7...
1FT6084-1AH7...
1FT6086-1AH7...
1FT6034-1AK7...
1FT6084-1AK7...
12.1
21.4
3
4.1
6.1
9.6
13.2
16.4
5.7
9.0
19.8
23.3
2.6
24.1
Cooling:
Internal air cooling
External air cooling
5.7 (7.6)
10.5 (14.8)
1.6 (2.2)
1.9 (2.6)
3.0 (4.0)
4.1 (5.5)
6.3 (8.5)
8.5 (11.4)
2.8 (3.8)
4.5 (6.0)
9.4 (12.6)
12.7 (17.0)
1.3 (1.7)
12.6 (16.9)
18
30
3
5
9
18
18
18
9
9
18
30
3
30
6SL3127 - 7 TE21-8AA3
6SL3127 - 1TE23-0AA3
6SL3127 - 7 TE13-0AA3
6SL3127 - 7 TE15-0AA3
6SL3127 - 7 TE21-0AA3
6SL3127 - 7 TE21-8AA3
6SL3127 - 7 TE21-8AA3
6SL3127 - 7 TE21-8AA3
6SL3127 - 7TE21-0AA3
6SL3127 - 7TE21-0AA3
6SL3127 - 7TE21-8AA3
6SL3127 - 1TE23-0AA3
6SL3127 - 7TE13-0AA3
6SL3127 - 1TE23-0AA3
1.5
1.5
1
1
1
1.5
1.5
1.5
1
1
1.5
1.5
1
1.5
0
1
4 x 1.5
4x4
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 2.5
4 x 1.5
4 x 1.5
4x4
4x4
4 x 1.5
4x4
6FX 7002-5 7 S21-....
6FX 7002-5 7 S41-....
6FX 7002-5 7 S01-....
6FX 7002-5 7 S01-....
6FX 7002-5 7 S01-....
6FX 7002-5 7 S21-....
6FX 7002-5 7 S21-....
6FX 7002-5 7 S31-....
6FX 7002-5 7 S01-....
6FX 7002-5 7 S01-....
6FX 7002-5 7 S41-....
6FX 7002-5 7 S41-....
6FX 7002-5 7 S01-....
6FX 7002-5 7 S41-....
Motor Module:
Single Motor Module
Double Motor Module
1
2
Type of power cable:
MOTION-CONNECT 800
MOTION-CONNECT 500
8
5
Without brake cores
With brake cores
C
D
For length code as well as power and signal cables, see MOTION-CONNECT connection system.
....
4
1) If the absolute encoder is used, Mrated is reduced by 10 %.
2) The current carrying capacity of the power cables complies with
EN 60204-1 for installation type C, for continuous
duty at an ambient air temperature of 40 °C (104 °F)
3) With default setting of the pulse frequency.
4)
Pcalc
[kW]
=
M0
[Nm] x nrated
9550
Pcalc
[HP]
=
M0
[Ibf-in] x
63000
nrated
Siemens PM 21 · 2008
4/17
Free Datasheet http://www.Datasheet4U.com

6 Page









1FT6062-1AH71 pdf, datenblatt
© Siemens AG 2008
Synchronous motors
1FT6 motors, standard type
Natural cooling
I Selection and ordering data
Motor type
(continued)
Static cur- Calculated
rent power
Pcalc 6)
I0 Pcalc
at M0
for M0
T=100 K T=100 K
∆∆
SINAMICS S120 Motor Module
Rated
Booksize format
output
current 5)
Irated
Order No.
Power cable with complete shield
Motor connection (and brake connection) via
power connector
Power
Cable
connector cross-
section 4)
Order No.
Pre-assembled cable
A
kW (HP)
A
Size
mm2
1FT6041-4AF7 ...
1FT6044-4AF7 ...
1FT6061-6AF7 ...
1FT6062-6AF7 ...
1FT6064-6AF7 ...
1FT6081-8AF7 ...
1FT6082-8AF7 ...
1FT6084-8AF7 ...
1FT6086-8AF7 ...
1FT6102-8AF7 ...
1FT6105-8AF7 ...
1FT6108-8AF7 ...
1FT6132-6AF7 ...
1.9
3.0
2.7
4.1
6.1
5.8
9.6
13.2
16.4
16.9
32
41
43
0.8 (1.1)
1.6 (2.2)
1.3 (1.7)
1.9 (2.6)
3.0 (4.0)
2.5 (3.4)
4.1 (5.5)
6.3 (8.5)
8.5 (11.4)
8.5 (11.4)
15.7 (21.1)
22.0 (29.5)
23.6 (31.7)
3
3
3
5
9
9
18
18
18
18
30 3)
45
45
6SL3127 - 7 TE13-0AA3
6SL3127 - 7 TE13-0AA3
6SL3127 - 7 TE13-0AA3
6SL3127 - 7TE15-0AA3
6SL3127 - 7 TE21-0AA3
6SL3127 - 7 TE21-0AA3
6SL3127 - 7 TE21-8AA3
6SL3127 - 7TE21-8AA3
6SL3127 - 7 TE21-8AA3
6SL3127 - 7TE21-8AA3
6SL3127 - 1 TE23-0AA3
6SL3127 - 1 TE24-5AA3
6SL3127 - 1 TE24-5AA3
1
1
1
1
1
1.5
1.5
1.5
1.5
1.5
1.5
3
3
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
4 x 2.5
4 x 2.5
4 x 10
4 x 10
4 x 10
6FX 7 002-5 7 S01-....
6FX 7 002-5 7 S01-....
6FX 7 002-5 7 S01-....
6FX 7 002-5 7 S01-....
6FX 7 002-5 7 S01-....
6FX 7 002-5 7 S21-....
6FX 7 002-5 7 S21-....
6FX 7 002-5 7 S21-....
6FX 7 002-5 7 S31-....
6FX 7 002-5 7 S31-....
6FX 7 002-5 7 S61-....
6FX 7 002-5 7 S14-....
6FX 7 002-5 7 S14-....
Cooling:
Internal air cooling
External air cooling
0
1
Motor Module:
Single Motor Module
Double Motor Module
1
2
Type of power cable:
MOTION-CONNECT 800
MOTION-CONNECT 500
Without brake cores
With brake cores
8
5
C
D
For length code as well as power and signal cables, see MOTION-CONNECT connection system.
....
4
1) If the absolute encoder is used, Mrated is reduced by 10 %.
2) Same flange as for IM B5 type, but with metric threaded insert in the
four mounting holes.
3) With the specified Motor Module, the motor cannot be fully utilized
with M0 at T = 100 K winding temperature rise.
If a Motor Module with a higher rating is used, you must check whe-
ther the specified power cable can be connected to it.
4) The current carrying capacity of the power cables complies with
EN 60204-1 for installation type C, for continuous
duty at an ambient air temperature of 40 °C (104 °F)
5) With default setting of the pulse frequency.
6)
Pcalc
[kW]
=
M0
[Nm] x nrated
9550
Pcalc
[HP]
=
M0
[Ibf-in] x
63000
nrated
Siemens PM 21 · 2008
4/23
Free Datasheet http://www.Datasheet4U.com

12 Page





SeitenGesamt 30 Seiten
PDF Download[ 1FT6062-1AH71 Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
1FT6062-1AH71motorsSiemens
Siemens

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche