Datenblatt-pdf.com


ZX-LD100 Schematic ( PDF Datasheet ) - Omron

Teilenummer ZX-LD100
Beschreibung ZX Series Smart Sensors
Hersteller Omron
Logo Omron Logo 




Gesamt 28 Seiten
ZX-LD100 Datasheet, Funktion
Smart Sensors (Laser Type)
ZX Series (ZX-L-N)
Ordering Information
Sensors
Sensor Heads (Reflective)
Optical system
Diffuse reflective
Beam shape
Spot beam
Line beam
Regular reflective
Spot beam
Line beam
*1. For an average count of 4,096.
Sensing distance
40±10 mm
100±40 mm
300±200 mm
40±10 mm
100±40 mm
300±200 mm
30±2 mm
Resolution*1
2 µm
16 µm
300 µm
2 µm
16 µm
300 µm
0.25 µm
Model
ZX-LD40
ZX-LD100
ZX-LD300
ZX-LD40L
ZX-LD100L
ZX-LD300L
ZX-LD30V
ZX-LD30VL
Sensor Heads (Through-beam)
Optical system
Through-beam
Measuring width
1-mm dia.
5 mm
10 mm
30 mm
*1. For an average count of 64.
Sensing distance
0 to 2000 mm
0 to 500 mm
Resolution*1
4 µm
12 µm
Model
ZX-LT001
ZX-LT005
ZX-LT010
ZX-LT030
Amplifier Units
Appearance
Power supply
DC
NPN
Output type
Model
ZX-LDA11-N
PNP
ZX-LDA41-N
Note: Compatible connection with the Sensor Head.
.
ZX Series (ZX-L-N) Smart Sensors (Laser Type)
1
Free Datasheet http://www.Datasheet4U.com






ZX-LD100 Datasheet, Funktion
Calculating Unit
Item
Applicable Amplifier Units
Current consumption
Ambient temperature
Ambient humidity
Connection method
Dielectric strength
Insulation resistance
Vibration resistance (destructive)
Shock resistance (destructive)
Materials
Weight (packed state)
ZX-CAL2
ZX-LDA11-N/41-N/ZX-EDA11/41/ZX-TDA11/41
12 mA max. (supplied from the Smart Sensor Amplifier Unit)
Operating: 0 to 50°C, Storage: 15 to 60°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
Connector
1,000 VAC, 50/60 Hz for 1 min
100 MΩ (at 500 VDC)
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Display: Acrylic, Case: ABS resin
Approx. 50 g
ZX-series Communications Interface Unit
Item
ZX-SF11
ZX-SF21
Current consumption
60 mA max. (supplied by the Amplifier Unit)
Applicable Amplifier Units
ZX Series
Applicable Amplifier Unit versions
ZX-LDA@1-N Ver. 1.000 or higher
ZX-EDA@1 Ver. 1.100 or higher
ZX-TDA@1 Ver. 1.000 or higher
Max. No. of Amplifier Units
5
Communications Communications RS-232C port (9-pin D-Sub Connector)
functions
port
USB
Communications CompoWay/F*
protocol
Baud rate
38,400 bps
Data configuration Data bits: 8, Parity: none, Start bits: 1, Stop bits: 1, Flow control: none
Indicators
Power supply: green, Sensor communications: green, Sensor communications error: red, External
terminal communications: green, External terminal communications error: red
Protective circuits
Reverse polarity protection
Ambient temperature
Operating: 0 to 50°C, storage: 15 to 60°C (with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min, Leakage current: 10 mA max.
Materials
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Accessories
Instruction sheet, 2 clamps
* Contact your OMRON representative for CompoWay/F communications specifications.
6 ZX Series (ZX-L-N) Smart Sensors (Laser Type)
Free Datasheet http://www.Datasheet4U.com

6 Page









ZX-LD100 pdf, datenblatt
Sensing Object Characteristics (Through-beam Sensors)
ZX-LT001
(For 0.02-mm-dia. pin gauge)
2
0
2
4
6
8
10
12
WD=50 mm
WD=250 mm
WD=450 mm
Sensing distance: 500 mm
Sensing object: 0.02-mm dia.
14 Pin gauge Y
16
18
2.5
Emitter side WD Receiver side
1.5 0.5 0 0.5
1.5 2.5
Light axis center
Detection position Y (mm)
ZX-LT001
(For 0.05-mm-dia. pin gauge)
2
0
2
4
6
8
10
12
14
16
18
2.5
WD=200 mm
WD=500 mm
WD=1,000 mm
WD=1,500 mm
WD=1,800 mm
Sensing distance: 2 m
Sensing object: 0.05-mm dia.
Pin gauge Y
Emitter
side
WD
Receiver side
1.5 0.5 0 0.5
1.5
Light axis center
2.5
Detection position Y (mm)
ZX-LT010
(For 0.1-mm-dia. pin gauge)
1 WD = 50 mm
WD = 250 mm
0.5 WD = 450 mm
Sensing distance: 500 mm
0 Sensing object: 0.1-mm dia.
0.5
1
1.5
2
2.5
3
8
Pin gauge Y
Emitter side
WD
40
Receiver
side
48
Light axis center
Detection position Y (mm)
Linearity Characteristics
ZX-LT005
4
WD=50 mm
3
WD=250 mm
WD=450 mm
Sensing distance: 500 mm
2
1
0
1
2
3
4
01
Emitter side
Receiver
side
WD
2 3 45
Light interruption (mm)
ZX-LT010
4
3
2
1
0
1
2
3
4
01
WD = 50 mm
WD = 250 mm
WD = 450 mm
Sensing distance: 500 mm
Emitter Receiver
side side
WD
2 3 45
Light interruption (mm)
ZX-LT005
(For 0.05-mm-dia. pin gauge)
1
WD=50 mm
WD=250 mm
0.5 WD=450 mm
Sensing distance: 500 mm
Sensing object: 0.05-mm dia.
0
0.5
1
1.5
2
2.5
3 5
Pin gauge Y
Emitter side WD Receiver side
2.5 0
2.5
Light axis center
5
Detection position Y (mm)
12 ZX Series (ZX-L-N) Smart Sensors (Laser Type)
Free Datasheet http://www.Datasheet4U.com

12 Page





SeitenGesamt 28 Seiten
PDF Download[ ZX-LD100 Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
ZX-LD100ZX Series Smart SensorsOmron
Omron
ZX-LD100LZX Series Smart SensorsOmron
Omron

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche