Datenblatt-pdf.com


ZWX300 Schematic ( PDF Datasheet ) - TDK-Lambda

Teilenummer ZWX300
Beschreibung (ZWX180 - ZWX300) 180W to 300W Industrial ATX Power Supplies
Hersteller TDK-Lambda
Logo TDK-Lambda Logo 




Gesamt 4 Seiten
ZWX300 Datasheet, Funktion
ZWX Series
180W to 300W
Industrial ATX Power Supplies
ZWX Features and Benefits
Features
• Convection Cooled Ratings
• Low Profile
• Industrial Grade
• No minimum loading
Specifications
MODELS
ITEMS
Input Voltage
Input Current
(1)(2)
Inrush Current
(2)
Power Factor
Leakage Current
Overcurrent Protection (3)
Overvoltage Protection (4)
Hold Up Time (Typ)
(1)
Efficiency
(1)(2)
Remote On/Off
DC Good PWR_OK
Remote Sense
Output Voltage Setpoint Accuracy
Output Voltage Adjustment
Line Regulation
Load Regulation
Ripple & Noise
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock (non operating)
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (WxHxD)
Warranty
V
A
A
-
mA
-
V
ms
%
-
-
-
-
-
mV
mV
mV
°C
°C
%RH
-
-
-
-
m/s2
-
-
-
g
mm
yrs
• 90 - 150W Convection Cooled Ratings
• 1U High
• ATX SFX 12V Compatible
• Power Factor Corrected
• Peak Power Ratings
• No Minimum Loading Required
Key Market Segments & Applications
Industrial & Rack Mount
PC Applications
Benefits
• No Forced Air or Fan Needed
• Fits into 1U High Enclosures
• Greater Reliability & Field Life
• Easier to Use
ZWX180
ZWX240
ZWX300
85-265VAC (47-63Hz)
1.9 / 1.0
2.6 / 1.3
3.2 / 1.6
14 / 28 Cold start 25°C ambient
Meets EN61000-3-2
< 0.75
>1.05% of forced air current rating (5s delay and manual reset on V1, 2 & 3)
+3.3V: 3.76 - 4.3V, +5V: 5.74 - 7V, +12V: 13.4 - 15.6V
20ms at 100VAC
81 / 84
High: Unit off, Low: Unit On (enabled). Meets SFX12V
High: Power supply is good. Meets SFX12V
+3.3V Only
±5% (all outputs)
None
3.3V: 20mV, 5V: 48mV, +12V: 48mV, -12V: 20mV, +5Vsb: 20mV
3.3V: 100mV, 5V: 300mV, +12V: 300mV, -12V: 100mV, +5Vsb: 100mV
3.3V: 120mV, 5V: 150mV, +12V: 150mV, -12V: 120mV, +5Vsb: 120mV
-10 to +70, derate linearly to 20% load from 50 to 70
-30 to +85°C
Operating: 30 - 90, Non operating: 10 - 95
Convection or forced air cooled (30CFM, 0.85m3/min)
I/P to Gnd 2kVAC (20mA), I/P to O/P 3kVAC (20mA), O/P to Gnd 500VAC (100mA) for 1 min.
>100Ω at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
< 392
UL60950-1, CSA60950-1, EN60950-1, EN50178 (OV II), CE Mark
EN55011/EN55022-B, FCC Class B, VCCI-B
EN61000-4-2, -3, -4, -5, -6, -8, -11
500 650 800
94 X 36 X 210
106 X 36 X 225
118 X 36 X 250
3 Years
ZWX Series
1
Free Datasheet http://www.datasheetlist.com/





SeitenGesamt 4 Seiten
PDF Download[ ZWX300 Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
ZWX300(ZWX180 - ZWX300) 180W to 300W Industrial ATX Power SuppliesTDK-Lambda
TDK-Lambda

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche