U1600 Series Handheld Digital Oscilloscopes
Data Sheet
Delivering more functionality and performance
with a handheld digital oscilloscope
Features
‡ Three-in-one solution: Dual
channel oscilloscope, True RMS
DMM, and Real-Time Data
Logger
‡ Large 4.5” color LCD display
‡ Up to 40 MHz bandwidth with
advanced triggering
‡ Up to 200 MSa/s sampling rate
‡ Up to 125 000 points recording
length
‡DXWRPDWLFVFRSH
measurement functions available
‡ 6,000-count DMM resolution with
built-in measurement
functions including voltmeter,
ohmmeter, and auxiliary meter
‡ Zoom and Dual Waveform Math
functions (additional FFT
function with four windowing
techniques available in U1604A/
U1604B)
‡ Full remote control and data
transfer via PC Link application
software
‡ USB 2.0 full-speed interface
connectivity
‡ Multi-language Quick Help
support
Introduction
The U1600 Series handheld digital
oscilloscope has a 4.5-inch LCD color
display, which helps to clearly distinguish
waveforms between two channels. This
U1600 Series provides a high performance
troubleshooting and quality assurance tool
for technical professionals in the
installation, maintenance, service, and
automotive industries. The U1600 Series
consists of four models: U1602A/U1602B –
20 MHz oscilloscope and U1604A/U1604B
– 40 MHz oscilloscope. Each model has a
real-time sampling rate of up to 200 MSa/s.
Users can use the Dual Waveform Math
(DWM) and Fast Fourier Transform (FFT)
functions (in the U1604A/U1604B model)
to perform quick waveform analyses in both
time and frequency domains.
The built-in 6000 resolution count true RMS
digital multimeter (DMM) comes with an
auto-range feature that gives users the
flexibility to perform quick and accurate
meter measurements including voltage,
resistance, and auxiliary measurements.
In addition, the standard versions of the
U1600 Series models also contain a data
logger function.
The series’ latest oscilloscopes, the
U1602B and U1604B come in vivid orange
cases, offering capabilities and functions
equivalent to the U1600A Series.
A scope, true RMS DMM, a real-
time data logger in one instrument
The U1600 Series is a robust, high
performance and reliable handheld wave-
form and meter measurement tool for
today’s challenging industrial
environments. Not only do these
instruments provide fully featured
oscilloscope functions, but also a 6,000-
count true RMS DMM with real-time data
logger. The DMM measurement functions
include a voltmeter (for DC voltage, AC
voltage and true RMS AC + DC voltage
measurements), an ohmmeter (for 2-wire
resistance, capacitance, diode and
continuity tests), and an auxiliary meter (for
temperature, ampere measurement)*.
* additional accessories required and offered as
optional
Downloaded from Elcodis.com electronic components distributor
Free Datasheet http://www.datasheet-pdf.com/

1 page




U1600 pdf
Probes
Probe attenuation factors
Coupling
Maximum probe input
Noise peak-to-peak
DC vertical offset accuracy
Single cursor accuracy
Dual cursor accuracy
Horizontal System
Range
Resolution
Reference position
Delay range (pre-trigger)
Delay range (post-trigger)
Analog Dt accuracy
Modes
RMS Jitter
Trigger System
Source
Modes
Selections
Edge
Pattern
Pulse Width
Video
Range
Level accuracy
Trigger sensitivity
Coupling
U1560-60001: 1:1 passive probe
U1561-60001: 10:1 passive probe
U1562-60001: 100:1 passive probe
1x, 10x, 100x
3 Vp-p, ~ 1 kHz
1x CAT III 300 VAC
10 x, 100x CAT III 600 VAC
3% of full scale or 5 mV, whichever is greater
± 0.1% div ± 2 mV ± 0.5% offset value
4% full scale
4% full scale
U1602A/U1602B: 50 ns to 50 s/div
U1604A/U1604B: 10 ns to 50 s/div
U1602A/U1602B: 2 ns
U1604A/U1604B: 400 ps
Left, center, right
15 divisions
1000 divisions
± 3% reading ± 0.4% screen
Main, XY, Roll
5% of horizontal scale or 5 ns, whichever is higher
Channel 1 and Channel 2
Auto, normal, single
Edge, pulse width, pattern, video
Trigger on a rising or falling edge of any source
Trigger at the beginning of a pattern of high, low levels and rising or falling
edge established conditions of AND, OR, NOR and NAND between the
channels.
200 ns to 10 s. Trigger when a positive or negative pulse width of any source
larger than, less than, equal to or not equal to duration.
Video trigger sensitivity: 0.7 division trigger level.
Available to both Channel 1 and Channel 2.
Analog progressive and interlaced video standards including NTSC,
PAL and SECAM.
Positive or negative sync pulse polarity.
Modes – all fields, even fields, odd fields or line 5 – 263 within a field.
± 4 divisions from center screen
± 0.5 divisions
DC to 5 MHz: 0.8 divisions
U1602A/U1602B: 5 MHz to 20 MHz – 1 division
U1604A/U1604B: 5 MHz to 40 MHz – 1 division
DC, AC (< 1 Hz), HF reject (> 50 kHz), LF reject (< 30 kHz), Noise reject
Downloaded from Elcodis.com electronic components distributor
5
Free Datasheet http://www.datasheet-pdf.com/

5 Page





U1600 arduino
www.agilent.com
www.agilent.com/find/handheldscope
Agilent Email Updates
www.agilent.com/find/emailupdates
Get the latest information on the
products and applications you select.
www.lxistandard.org
LXI is the LAN-based successor to
GPIB, providing faster, more efficient
connectivity. Agilent is a founding
member of the LXI consortium.
Agilent Channel Partners
www.agilent.com/find/channelpartners
Get the best of both worlds: Agilent’s
measurement expertise and product
breadth, combined with channel
partner convenience.
Remove all doubt
Our repair and calibration services
will get your equipment back to you,
performing like new, when
promised. You will get full value out
of your Agilent equipment through-
out its lifetime. Your equipment
will be serviced by Agilent-trained
technicians using the latest factory
calibration procedures, automated
repair diagnostics and genuine parts. You
will always have the utmost confidence
in your measurements. For informa-
tion regarding self maintenance of this
product, please contact your Agilent
office.
Agilent offers a wide range of additional
expert test and measurement services
for your equipment, including initial
start-up assistance, onsite education
and training, as well as design, system
integration, and project management.
For more information on repair and
calibration services, go to:
www.agilent.com/find/removealldoubt
For more information on Agilent
Technologies’ products, applications or
services, please contact your local Agilent
office. The complete list is available at:
www.agilent.com/find/contactus
Americas
Canada
Latin America
United States
(877) 894 4414
305 269 7500
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Thailand
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
1 800 226 008
Europe & Middle East
Austria
Belgium
Denmark
Finland
France
43 (0) 1 360 277 1571
32 (0) 2 404 93 40
45 70 13 15 15
358 (0) 10 855 2100
0825 010 700*
*0.125 /minute
Germany
49 (0) 7031 464 6333
Ireland
1890 924 204
Israel
972-3-9288-504/544
Italy 39 02 92 60 8484
Netherlands 31 (0) 20 547 2111
Spain
34 (91) 631 3300
Sweden
0200-88 22 55
Switzerland
0800 80 53 53
United Kingdom 44 (0) 118 9276201
Other European Countries:
www.agilent.com/find/contactus
Revised: October 1, 2009
Product specifications and descriptions
in this document subject to change
without notice.
© Agilent Technologies, Inc. 2009
Printed in USA, December 4, 2009
5989-5576EN
Downloaded from Elcodis.com electronic components distributor
Free Datasheet http://www.datasheet-pdf.com/

11 Page







PáginasTotal 11 Páginas
PDF Descargar[ Datasheet U1600.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
U1600Handheld Digital OscilloscopesAgilent
Agilent
U1600AHandheld Digital OscilloscopesAgilent
Agilent
U1602(U1602 / U1603) Energy Control SystemECS
ECS
U1603(U1602 / U1603) Energy Control SystemECS
ECS

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar