DataSheet.es    


PDF HP206C Data sheet ( Hoja de datos )

Número de pieza HP206C
Descripción I2C PRECISION BAROMETER AND ALTIMETER
Fabricantes HOPERF 
Logotipo HOPERF Logotipo



Hay una vista previa y un enlace de descarga de HP206C (archivo pdf) en la parte inferior de esta página.


Total 12 Páginas

No Preview Available ! HP206C Hoja de datos, Descripción, Manual

HP206C
I2C PRECISION BAROMETER AND ALTIMETER
Features
ƒ 1.8V to 3.6V Supply Voltage
ƒ Full Data Compensation
ƒ Command-based Reading, Compensated (Optional)
- Pressure: 20-bit Measurement (Pascals)
- Altitude: 20-bit Measurement (Meters)
- Temperature: 20-bit Measurement (°Celsius)
ƒ Configurable ADC Decimation Rate via Commands
ƒ Programmable Events and Interrupt Controls
ƒ Altitude Resolution down to 0.01 meter
ƒ High-speed I2C Digital Output Interface (Up to 10 MHz)
Application Examples
ƒ High Precision Mobile Altimeter / Barometer
ƒ Industrial Pressure and Temperature Sensor System
ƒ Automotive Systems
ƒ Personal Electronics Altimetry
ƒ Adventure and Sports watches
ƒ Medical Gas Control System
ƒ Weather Station Equipment
ƒ Indoor Navigation and Map Assist
ƒ Heating, Ventilation, Air Conditioning
Descriptions
The HP206C employs a MEMS pressure sensor with an I2C
interface to provide accurate Temperature, Pressure or Altitude
data. The sensor Pressure and Temperature outputs are digitized
by a high resolution 24-bit ADC. The Altitude value is calculated
by a specific patented algorithm according to the pressure and
temperature data. Data compensation is integrated internally to
save the effort of the external host MCU system. Easy
command-based data acquisition interface and programmable
interrupt control is available. Typical active supply current is 5.3
uA per measurement-second while the ADC output is filtered and
decimated by 256. Pressure output can be resolved with output in
fractions of a Pascal, and Altitude can be resolved in 0.01 meter.
The HP206C is offered in a 6.8 mm x 6.2 mm x 0.635(+0.2) mm
package and specified for operation from -40°C to 85°C.
Primary version. Do not guarantee all parameters.
Top view
Free Datasheet http://www.datasheet4u.com/

1 page




HP206C pdf
2. Function Descriptions
GENERAL
The HP206C is a high precision barometer and altimeter 
that measures the pressure and the temperature by an 
internal 24bit ADC and compensates them by a 
patented algorithm. The fullycompensated values can 
be read out via the I2C interface by external MCU. The 
uncompensated values can also be read out in case the 
user wants to perform their own data compensation. The 
devices can also compute the value 
of altitude according to the measured pressure and 
temperature. 
 
Furthermore, the device allows the user to setup the 
temperature, pressure and altitude threshold values for 
various events. Once the device detects that a certain 
event has happened, a corresponding interrupt will be 
generated and sent to the external MCU. Also, multiple 
useful interrupt options are available to be used by the 
user. 
 
 
FACTORY CALIBRATION
Every device is individually factory calibrated for 
sensitivity and offset for both of the temperature and 
pressure measurements. The trim values are stored in 
the onchip 128Byte NonVolatile Memory (NVM). In 
normal situation, further calibrations are not necessary 
to be done by the user. However, in order to realize the 
highest possible accuracy, the device allows the users to 
burn their own trim values into the empty bank of the 
NVM using the provided CMOSTEK NVM PROGRAMMER. 
Once a new bank of the NVM is programmed, the 
original factory calibrated trim values will be replaced by 
the newly programmed trim values. 
 
Please refer to the document of AN301 for the details of 
NVM programming and the AN302 for the details of 
computing the correct trim values for each different 
device. 
 
 
AUTOMATIC POWER-UP
Once the device detects a valid VDD is externally 
supplied, an internal PowerOnReset (POR) is generated 
and the device will automatically enter the powerup 
initialization sequence. After that the device will enter 
the sleep state. Normally the entire powerup sequence 
consumes about 400 us. 
HP206C
The user can scan a DEV_RDY bit in the INT_SRC register 
in order to know whether the device has finished its 
powerup sequence. This bit appears to 1 when the 
sequence is done. The device stays in the sleep state 
unless it receives a proper command from the external 
MCU. This will help to achieve minimum power 
consumptions. 
 
 
SENSOR OUTPUT CONVERSION
For each pressure measurement, the temperature is 
always being measured prior to pressure measurement 
automatically, while the temperature measurement can 
be done individually. The conversion results are stored 
into the embedded memories that retain their contents 
when the device is in the sleep state. 
 
The conversion time depends on the value of the DSR 
parameter sent to the device within the ADC_CVT 
command. Six options of the DSR can be chosen, range 
from 128, 256  to 4096. The below table shows the 
conversion time according to the different values of 
DSR: 
 
Table 6: Conversion Time VS DSR
Conversion Time (ms)
DSR
Temperature Only
Temperature and
Pressure (or Altitude)
128 2.1
4.1
256 4.1
8.2
512 8.2
16.4
1024
16.4
32.8
2048
32.8
65.6
4096
65.6
131.1
The higher DSR will normally achieve higher measuring 
precision, but consume more time and power. 
 
The conversion results can be compensated or 
uncompensated. The user can enable/disable the 
compensation by setting the PARA register before 
performing the conversions. 
 
 
ALTITUDE COMPUTATION
The device can compute the altitude according to the 
measured pressure and temperature. The altitude value 
is updated and available to read as soon as the 
temperature and pressure measurement is done. 
3
Free Datasheet http://www.datasheet4u.com/

5 Page





HP206C arduino
6. PACKAGE INFORMATION
HP206C
Mechanical Dimension (unit: mm)
9
Free Datasheet http://www.datasheet4u.com/

11 Page







PáginasTotal 12 Páginas
PDF Descargar[ Datasheet HP206C.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
HP206CI2C PRECISION BAROMETER AND ALTIMETERHOPERF
HOPERF

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar