Teilenummer | OS-5060A |
|
Beschreibung | Analog Oscilloscope Operation Manual | |
Hersteller | EZ Digital | |
Logo | ||
Gesamt 30 Seiten Analog Oscilloscope
Operation Manual
Free Datasheet http://www.datasheet4u.com/
CONTENTS
1. INTRODUCTION
1-1. SPECIFICATION ------------------------------------------- 7
1-2. PRECAUTIONS -------------------------------------------- 10
2. OPERATING INSTRUCTIONS
2-1. FUNCTION of CONTROLS -------------------------------- 13
2-1-1. Display and Power Blocks -------------------------- 13
2-1-2. Vertical Amplifier Block ------------------------------ 14
2-1-3. Sweep and Trigger Blocks -------------------------- 16
2-1-4. Miscellaneous Features ------------------------------ 18
2-2. BASIC OPERATING PROCEDURES
2-2-1. Preliminary Control Settings and Adjustments -- 19
2-2-2. Signal Connections ------------------------------------ 22
2-2-3. Signal Trace Operation ------------------------------- 23
2-2-4. Dual Trace Operation --------------------------------- 25
2-2-5. Trigger Options ----------------------------------------- 27
2-2-6. Additive and Differential Operation ------------------ 30
2-2-7. X-Y Operation --------------------------------------------- 31
2-2-8. Delayed-time base Operation ------------------------- 32
2-3. MEASUREMENT APPLICATIONS
2-3-1. Amplitude Measurements ---------------------------- 35
2-3-2. Time Interval Measurements ------------------------ 39
2-3-3. Frequency Measurement ----------------------------- 41
2-3-4. Phase Difference Measurement -------------------- 43
2-3-5. Rise Time Measurement ------------------------------ 47
Free Datasheet http://www.datasheet4u.com/
6 Page 1-2-2. Installation and handling precautions
When placing the OS-5060A in service at your workplace, observe the following
precautions for best instrument performance and longest service life.
1. Avoid placing this instrument in an extremely hot or cold place. Specifically, don’t leave
this instrument in a close car, exposed to sunlight in midsummer, or next to a space heater.
2. Don’t use this instrument immediately after bringing it in from the cold. Allow
time for it to warm to room temperature. Similarly, don’t move it from a
warm place to a very cold place, as condensation might impair its operation.
3. Do not expose the instrument to wet or dusty environments.
4. Do not place liquid-filled containers (such as coffee cups) on top of this
instrument. A spill could seriously damage the instrument.
5. Do not use this instrument where it is subject to severe vibration, or strong blows.
6. Do not place heavy objects on the case, or otherwise block the ventilation holes.
7. Do not use this oscilloscope in strong magnetic fields, such as near motors.
8. Do not insert wires, tools, etc. through the ventilation holes.
9. Do not leave a hot soldering iron near the instrument.
10. Do not place this scope face down on the ground, or damage to the knobs may result.
11. Do not use this instrument upright while BNC cables are attached to the
rear-panel connectors. This will damage the cable.
12. Do not apply voltages in excess of the maximum ratings to the input connectors or
probes.
13. This oscilloscope is to use UL listed double insulated probes only.
Free Datasheet http://www.datasheet4u.com/
12 Page | ||
Seiten | Gesamt 30 Seiten | |
PDF Download | [ OS-5060A Schematic.PDF ] |
Teilenummer | Beschreibung | Hersteller |
OS-5060A | Analog Oscilloscope Operation Manual | EZ Digital |
Teilenummer | Beschreibung | Hersteller |
CD40175BC | Hex D-Type Flip-Flop / Quad D-Type Flip-Flop. |
Fairchild Semiconductor |
KTD1146 | EPITAXIAL PLANAR NPN TRANSISTOR. |
KEC |
www.Datenblatt-PDF.com | 2020 | Kontakt | Suche |