Datenblatt-pdf.com


G3PC Schematic ( PDF Datasheet ) - Omron

Teilenummer G3PC
Beschreibung SSR
Hersteller Omron
Logo Omron Logo 




Gesamt 6 Seiten
G3PC Datasheet, Funktion
SSR with Failure Detection Function
G3PC
Detects failures in SSRs used for heater
temperature control and simultaneously
outputs alarm signals. This product
supports the safe design of heater control
systems, and contributes to maintenance
improvements by the user.
Main detection items:
SSR short-circuits and SSR open-circuits
Alarm output possible to NPN/PNP-input devices.
The failure-detection function is built-in and power is supplied
from the main circuit power supply making wiring simple.
Slim design (width: 22.5 mm) incorporating radiator.
In addition to screw mounting, DIN track mounting is also pos-
sible.
Conforms to international standards (IEC, UL, and CSA).
Ordering Information
I List of Models
Insulation method
Phototriac coupler
Zero-cross function
Yes
Indicators
Yes
(See page 75)
I Accessories (Order Separately) www.DataSheet.co.kr
Name
Mounting Track
Dimensions
50 cm (l) × 7.3 mm (t)
1 m (l) × 7.3 mm (t)
1 m (l) × 16 mm (t)
Model number
PFP-50N
PFP-100N
PFP-100N2
Applicable output load
20 A, 100 to 240 VAC
(resistive load: AC, Class1)
Model number
G3PC-220B-VD
Specifications
I Ratings (At an Ambient Temperature of 25°C)
Detection Power Supply
Main Circuit
Rated power supply voltage
Operating voltage range
Current consumption
100 to 240 VAC (50/60 Hz)
75 to 264 VAC (50/60 Hz)
15 mA AC max. (at 200 VAC)
Operating Circuit
Input method
Rated input voltage
Operating input voltage
range
Must-operate voltage
Reset voltage
Input current
Voltage input
12 to 24 VDC
9.6 to 30 VDC
9.6 VDC max.
1 VDC min.
7 mA DC max. (at rated input voltage)
Rated load voltage
Operating voltage range
Rated carry current
Minimum load current
Inrush current resistance (peak value)
Permissible (I2t)
Applicable load
(with Class-1 AC resistive load)
100 to 240 VAC (50/60 Hz)
75 to 264 VDC (50/60 Hz)
20 A (Ta = 40)
0.1 A
220 A (60 Hz, 1 cycle)
260 A2S
4 kW (at 200 VAC)
Alarm Output
Output OFF collector voltage
Maximum carry current
Output form
30 VDC max.
0.1 A
Independent NPN open collector
SSR with Failure Detection Function G3PC
J-71
Datasheet pdf - http://www.DataSheet4U.net/






G3PC Datasheet, Funktion
Precautions
Refer to the Technical Information for SSRs (Cat. No. J137) for gen-
eral precautions.
I Correct Use
Before Actual Operation
1. In actual operation, the G3PC may cause accidents that were
unforeseeable at the theoretical stage. Therefore it is necessary
to test the G3PC under a variety of conditions that are possible.
As for the characteristics of the G3PC, it is necessary to consider
the differences between G3PC Units.
2. The ratings in this datasheet are for testing in a temperature
range of 15 to 30°C, a relative humidity range of 25% to 85%, and
an atmospheric pressure range of 88 to 106 kPa. When testing
operation, it is necessary to confirm correct operation not only
with the actual load that will be used, but also at the same ambi-
ent conditions as for actual operation.
Mounting Method
DIN Track Mounting
When mounting to a DIN track, mount the G3PC until it clicks into
place, otherwise it become loose during use and fall. Fix both ends
with end plates.
Panel Mounting
When mounting directly to a panel, observe the following conditions:
Screw diameter: M4
Tightening torque: 0.98 to 1.47 N·m
Vertical Mounting
Horizontal Mounting
Wiring
When using crimp terminals, observe the terminal clearances
shown below.
Main Circuit Power Supply Operating Input/Alarm Output
(Terminals 1 to 3)
(Terminals A1, A2, X1, and X2)
10 7.0
12.4
10
M3.5
Be sure that all lead wires are of a thickness appropriate for the
current.
The output terminals are charged, and touching them may result in
electric shock, even when the G3PC is OFF. Separate the outputs
from the power supply by installing a circuit-breaker at a higher
level in the circuit.
Tightening Torque
Be sure to tighten the screws to the specified torques given below.
Not doing so may result in malfunction.
Terminal number
A1, A2, X1, X2
1/L1, 2/T1, 3
Screw terminal
diameter
M3.5
M4
Tightening torque
0.59 to 1.18 N·m
0.98 to 1.47 N·m
Panel
Panel
Note: Use the G3PC at a load current of 50% of the rated load current
when it is mounted horizontally.
Side-by-side Mounting
www.DataSheet.co.kr
Wiring duct
80 mm min.
5 mm
80 mm min.
Wiring duct
Note: Use the G3PC at a load current of 80% of the rated load current
when it is mounted side-by-side.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. J127-E1-02
In the interest of product improvement, specifications are subject to change without notice.
J-76
SSR with Failure Detection Function G3PC
Datasheet pdf - http://www.DataSheet4U.net/

6 Page







SeitenGesamt 6 Seiten
PDF Download[ G3PC Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
G3PAExtremely Thin Relays IntegratedOMRON
OMRON
G3PA-VDExtremely Thin Relays IntegratedOMRON
OMRON
G3PCSSROmron
Omron
G3PC-220B-VDSSROmron
Omron
G3PFSolid State RelaysOmron
Omron

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche