Datenblatt-pdf.com


DF-G1 Schematic ( PDF Datasheet ) - Banner Engineering

Teilenummer DF-G1
Beschreibung Expert Dual Display Fiber Amplifier Manual
Hersteller Banner Engineering
Logo Banner Engineering Logo 




Gesamt 27 Seiten
DF-G1 Datasheet, Funktion
www.DataSheet.co.kr
DF-G1 - Expert Dual Display Fiber Amplifier Manual
Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies
Features
• Easy to read dual digital displays show both signal level and threshold simultaneously
• Lever action fiber clamp provides stable, reliable, and trouble-free fiber clamping
• Simple user interface ensures easy sensor set-up and programming via displays and
switches/buttons, or remote input teach wire
Expert TEACH and SET methods ensure optimal gain and threshold for all applica-
tions, especially low contrast applications
• User has full control over all operating parameters: threshold, Light Operate or Dark
Operate, output timing functions, gain level, and response speed
• Thermally stable electronics minimize warm-up drift and the effect of side-by-side
mounting of multiple fiber amplifiers
• ECO (economy) display mode reduces amplifier power consumption by 25%
• Cross talk avoidance algorithm allows two sensors to operate in close proximity for
many applications
• Response speeds of: 200 µs (High Speed), 500 µs (Standard), 2 ms (Long Range),
and 5 ms (Extra Long Range) allow operator to optimize for fast or long distance ap-
plications
• Sleek 10 mm wide housing mounts to 35 mm DIN standard rail
• Visible red LED sensing beam
Models
Model
DF-G1-NS-2M
DF-G1-PS-2M
DF-G1-NS-Q3
DF-G1-PS-Q3
DF-G1-NS-Q7
DF-G1-PS-Q7
Outputs
Single NPN
Single PNP
Single NPN
Single PNP
Single NPN
Single PNP
Connector*
2 m (6.5') cable, 4-wire
150 mm (6") PVC pigtail, M8 Pico QD connector, 4-
pin
Integral M8 Pico QD connector, 4-pin
* Connection options: A model with a QD connector requires a mating cordset (see Quick-Disconnect Cordsets on page 26).
For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G1-NS-9M).
For M12 Euro QD pigtail change the suffix 2M to Q5 in the 2 m model number (example, DF-G1-NS-Q5).
WARNING: Not To Be Used for Personnel Protection
Never use this product as a sensing device for personnel protection. Doing so could lead to seri-
ous injury or death. This product does NOT include the self-checking redundant circuitry necessary to
allow its use in personnel safety applications. A sensor failure or malfunction can cause either an ener-
gized or de-energized sensor output condition.
P/N 161999 Rev. A
1/12/2012
0 161999 7
Datasheet pdf - http://www.DataSheet4U.net/






DF-G1 Datasheet, Funktion
www.DataSheet.co.kr
DF-G1 - Expert Dual Display Fiber Amplifier Manual
Remote Input
The remote input may be used to perform TEACH/SET methods and to program the sensor remotely. Connect the white input wire of the
sensor to ground (0V dc), with a remote switch connected between them. Pulse the remote input according to the diagram shown below
in Figure 6. Follow the instructions in the TEACH/SET sections in Adjust Mode on page 7 to perform a TEACH/SET method.
TEACH methods and remote programming modes may be exited either after a 60-second timeout or by holding the remote input low for >
2 seconds, the sensor will return to RUN mode without saving any new settings.
Figure 4. Remote Input Flowchart
6
www.bannerengineering.com - tel: 763-544-3164
P/N 161999 Rev. A
Datasheet pdf - http://www.DataSheet4U.net/

6 Page









DF-G1 pdf, datenblatt
www.DataSheet.co.kr
Window SET
SET Button
Remote Input
0.04 seconds < "Click" < 0.8 seconds 0.04 seconds < T < 0.8 seconds
DF-G1 - Expert Dual Display Fiber Amplifier Manual
Result
Note: TEACH Selection must be programmed to wind SEt (see Program Mode on page 3 )
Enter Ad-
just Mode
• Set Mode switch to ADJ
No action required; sensor is Display: Red - Signal Level;
ready for Window SET method Green - Threshold
SET Sens-
ing Condi-
tion
Return to
RUN Mode
• Present sensing condition
• Click the SET rocker but-
ton
• Present sensing condition Threshold Condition Accep-
• Single-pulse the remote in- ted
put Displays read "wInd SEt" then
T
alternate "PASS" with % Off-
set*; Sensor returns to Adjust
mode
Threshold Condition Unac-
ceptable
Displays read "wInd SEt" then
alternate "FAIL" with minimum
% Offset* for sensing condition;
Sensor returns to Adjust mode
• Move Mode switch to RUN No action required; sensor re-
turns to RUN mode automati-
cally
Display: Red - Signal Level;
Green - Window Center (see
Figure below for instructions on
how to display upper and lower
thresholds)
Figure 8.
* See Troubleshooting on page 19 for more explanation of the % Offset displayed after the Window SET method
12
www.bannerengineering.com - tel: 763-544-3164
P/N 161999 Rev. A
Datasheet pdf - http://www.DataSheet4U.net/

12 Page





SeitenGesamt 27 Seiten
PDF Download[ DF-G1 Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
DF-G1Expert Dual Display Fiber Amplifier ManualBanner Engineering
Banner Engineering
DF-G1Expert Fiber Amplifier Install SheetBanner Engineering
Banner Engineering

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche