Datenblatt-pdf.com


STM-S3 Schematic ( PDF Datasheet ) - Connor-Winfield

Teilenummer STM-S3
Beschreibung STRATUM 3 SIMPLIFIED CONTROL TIMING MODULES
Hersteller Connor-Winfield
Logo Connor-Winfield Logo 




Gesamt 6 Seiten
STM-S3 Datasheet, Funktion
C O N N O R THE CONNOR-WINFIELD CORP.
W I N F I E L D 2111 COMPREHENSIVE DRIVE.
AURORA, IL 60505.
FAX (630) 851-5040.
PHONE (630) 851-4722
HTTP://WWW.CONWIN.COM
NETWORK ELEMENT TIMING GENERATOR
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (STM-S3)
DESCRIPTION
The Connor-Winfield Stratum 3 Simplified Control
Timing Module acts as a complete system clock module for general
Stratum 3 timing applications. The STM is designed for external
control functions. Full external control input allows for selection
and monitoring of any of four possible operating states: 1)
Holdover, 2) External Reference #1, 3) External Reference #2, and
4) Free Run. The table below illustrates the control signal inputs
and corresponding operational states:
In the absence of External Control Inputs (A,B), the STM
enters the Free Run mode and signals an External Alarm. The
STM will enter other operating modes upon application of a proper
control signal. Mode 1 operation (A=1, B=0) results in an output
signal that is phase locked to the External Reference Input #1.
Mode 2 operation (A=0, B=1) results in an output signal that is
phase locked to External Reference Input #2. Holdover mode
operation (A=1, B=1) results in an output signal at or near the
frequency as determined by the latest (last) locked-signal input
values and the holdover performance of the STM.
Alarm signals are generated at the Alarm Output during
Holdover and Free Run operation. Alarm Signals are also
generated by loss-of-lock, loss of Reference, and by a Tune-Limit
indication from the PLL. A Tune-Limit alarm signal indicates
that the VCXO tuning voltage is approaching within 10% the limits
of its lock capability and that the External Reference Input may
be erroneous. A high level indicates an alarm condition. Real-
time indication of the operational mode is available at unique
operating mode outputs on pins 1-4.
Control loop filters effectively attenuate any reference
jitter and smooth out phase transients.
STM-S3 PIN ASSIGNMENT
+5Vdc
EX REF 1
GND
EX REF 2
GND
N/C
CLK_OUT
GND
N/C
SYNC_OUT
GND
PLL TVL
BOTTOM VIEW
HLDOVR
REF 1
REF 2
FRERUN
GND
N/C
N/C
N/C
N/C
ALARM OUT
CNTL A
CNTL B
CNTL A
CNTL B
EX REF 1
EX REF 2
0
1
2
2:4 3
BLOCK DIAGRAM
FRERUN
REF 1
REF 2
HOLDOVER
PLL TVL
FREE RUN
HOLDOVER
2:1
MUX
PHASE
COMPARATOR
LOCK AND
DETECTION
DAC
FILTERS
TUNING
VOLTAGE
MONITOR
PLL TVL
DAC
STRATUM3
VCXO
FIFO
STRATUM3
TCXO
STM-S3
ALARM OUT
2:1
MUX
SYNC_OUT
CLK_OUT
CONTROL
INPUT
AB
www0.DataS0heet4U.com
External
1 0 Reference
#1
External
0 1 Reference
#2
11
OPERATIONAL MODE
Free Run (Default)
Normal
Tune Limit
LOS + LOL
Normal
Tune Limit
LOS + LOL
Holdover
REF 1
0
1
1
1
0
0
0
0
REF 2
HLDOVR
FRERUN
PLL_TVL*
ALARM
OUTPUT
00 10 1
00000
000 11
0000 1
10 0 0 0
100 11
1000 1
0 100 1
INT Specifications subject to change without notice.
DATA SHEET #: _T_M__0_0_0______ PAGE___1___ OF ___6____ REV:__0_4_____ DATE:___1_/_3_/_2_0_0_0__ © Copyright 2000 Connor-Winfield all rights reserved.






STM-S3 Datasheet, Funktion
C O N N O R THE CONNOR-WINFIELD CORP.
W I N F I E L D 2111 COMPREHENSIVE DRIVE.
AURORA, IL 60505.
FAX (630) 851-5040.
PHONE (630) 851-4722
HTTP://WWW.CONWIN.COM
NETWORK ELEMENT TIMING GENERATOR
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (STM-S3)
STM-S3
PACKAGE
WITH COVER
.030
(.762mm)
.180
(4.572mm)
.192
(4.876mm)
3.937
(100mm)
24
23
22
21
20
19
18
17
16
15
14
2.400
(60.96mm)
2.000
(50.80mm)
“A-A”
1
2
3
4
5
6
7
8
9
.300 TYP (22)
(7.62mm)
10
11
.078 (1.98mm)
.040 (1.02mm)
.120
(3.05mm)
DETAIL “A-A”
.200
(5.08mm)
.600
(15.24mm)
PIN 1
.445
(11.30mm)
13
12
BOTTOM VIEW
www.DataSheet4U.com
APPLICATIONS CIRCUIT DIAGRAM
5 VOLT DC
POWER
SUPPLY
BBLLOOCCKK DDIIAAGGRRAAMM
NETWORK
TIMING
REFERENCE
INPUT
eg. BITS CLOCK,etc.
FREE RUN CLOCK
COPY
SYSTEM
CLOCK
+5Vdc
EX REF 1
GND
EX REF 2
GND
CLK_OUT
GND
SYNC_OUT
GND
HOLDLAST
REF 1
REF 2
FRERUN
GND
ALARM OUT
CNTL A
CNTL B
PLL TVL
SYSTEM
CONTROL
AND DATA
INPUTS
LOSS OF
REFERENCE
MONITOR
SECTION
MECHANICAL CHARACTERISTICS
MECHANICAL SHOCK 883D 2002 CONDITION B
1500 G’s 0.5 ms.
VIBRATION 883D-2007 C0NDITION A
0.06” DA or 20 g Peak Acceleration 20 to 2000 Hz.
ENVIRONMENTAL CHARACTERISTICS
TEMPERATURE CYCLE 883D METHOD 1010.7 CONDITION B
10 Cycles -55 to +125 Degrees C.
HTOB - HIGH TEMPERATURE OPERATING BIAS
1000 Hours +125 Degrees C.
FACTORY RELIABILITY AUDIT
TEMPERATURE CYCLE
500 Cycles -55 to +125 Degrees C.
HTOB - HIGH TEMPERATURE OPERATING BIAS
1000 Hours +125 Degrees C.
PARTS TO BE QUALIFIED TO BELLCORE TR-NWT-00357
TEMPERATURE CYCLE
-40 to +85 Degrees C.
72 HOUR BURN-IN
+25 Degrees C.
INT Specifications subject to change without notice.
DATA SHEET #: _T_M__0_0_0______ PAGE___6___ OF __6_____ REV:__0_4_____ DATE:___1_/_3_/_2_0_0_0__ © Copyright 2000 Connor-Winfield all rights reserved.

6 Page







SeitenGesamt 6 Seiten
PDF Download[ STM-S3 Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
STM-S3STRATUM 3 SIMPLIFIED CONTROL TIMING MODULESConnor-Winfield
Connor-Winfield
STM-S3EStratum 3E Timing ModuleConnor-Winfield
Connor-Winfield

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche