Solid State Relays with Built-in Current Transformer
G3PF
www.DataSheet4U.com
CSM_G3PF_DS_E_5_1
A New-concept SSR with Built-in
Current Transformer.
Heater Burnout and SSR Short-
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.
Refer to Safety Precautions for All Solid State
Relays and Safety Precautions on page 10.
Ordering Information
List of Models
Input terminals
M3 terminals
Screwless clamp
terminals
(detachable)
Compact slotted
screw terminals
(detachable)
Isolation method Zero cross function Operation indicator
Phototriac-
coupler
Yes
Yes
Alarm output
1 output
2 outputs (Heater
Burnout Detection,
SSR Short-circuit
Failure Detection)
2 outputs (Heater
Burnout Detection,
SSR Short-circuit
Failure Detection)
Applicable load (See note.)
2 to 25 A, 100 to 240 VAC
2 to 35 A, 100 to 240 VAC
2 to 25 A, 200 to 480 VAC
2 to 35 A, 200 to 480 VAC
2 to 25 A, 100 to 240 VAC
2 to 35 A, 100 to 240 VAC
2 to 25 A, 200 to 480 VAC
2 to 35 A, 200 to 480 VAC
2 to 25 A, 100 to 240 VAC
2 to 35 A, 100 to 240 VAC
2 to 25 A, 200 to 480 VAC
2 to 35 A, 200 to 480 VAC
Model
G3PF-225B
G3PF-235B
G3PF-525B
G3PF-535B
G3PF-225B-CTB
G3PF-235B-CTB
G3PF-525B-CTB
G3PF-535B-CTB
G3PF-225B-STB
G3PF-235B-STB
G3PF-525B-STB
G3PF-535B-STB
Note: The load current depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data for details.
Specifications
Certification
CSA 22.2 No. 14, EN 60947-4-3, UL508 (The G3PF-2@@B-@@@ Series)
Ratings
Detection Power Supply
Operation Input
Rated power supply voltage
Operating voltage range
Current consumption
24 VDC
20.4 to 26.4 VDC
50 mA DC max. (at 24 VDC)
Alarm Output
Output OFF collector voltage
Maximum carry current
Output form
Minimum load current
30 VDC max.
100 mA
NPN open collector (ON when error is
detected.)
0.1 mA
Input method
Voltage input
Rated input voltage
12 to 24 VDC
Operating input voltage range 9.6 to 26.4 VDC
Operate voltage
9.6 VDC max.
Release voltage
1.0 VDC min.
Input current
5 mA DC max. (at 12 VDC)
10 mA DC max. (at 24 VDC)
1






G3PF Datasheet, Funktion
Engineering Data
Load Current vs. Ambient Temperature
G3PF-@25B
G3PF-@25B-@TB
40
30
G3PF-225B
25
20
15
10
Individual or
close mounting
G3PF-@35B
G3PF-@35B-@TB
40
G3PF-235B
35
30
Close mounting
21
20
17
10
Individual mounting
G3PF
www.DataSheet4U.com
0
30 20 0
20 40 60 80 100
Ambient temperature (°C)
0
30 20 0
20 40 60 80 100
Ambient temperature (°C)
Note: The data above assumes that the Unit is mounted on a vertical surface. If it is mounted on a horizontal surface, reduce the load current shown above by 30%.
One Cycle Surge Withstand Current
Non-repetitive input (For repetitive input, the figure will be less than the value for surge current withstand
indicated by the broken line.)
G3PF-@25B
G3PF-@25B-@TB
G3PF-@35B
G3PF-@35B-@TB
250 500
200 400
150
100
50
0
10 30 50 100 300 500 1,000 3,000 5,000
Energized time (ms)
300
200
100
0
10 30 50 100 300 500 1,000 3,000 5,000
Energized time (ms)
6

6 Page









G3PF pdf, datenblatt
(5) G3PF and Duct (or Other Object Blocking Airflow)
Relationship
Incorrect Example
Duct or other object
blocking airflow
Countermeasure 1
30 mm max.
(No more than 1/3 the G3PF
depth is recommended.)
Countermeasure 2
Airflow
Vertical
direction
Base
G3PF
Duct or other
airflow-blocking object
If the depth direction of the
G3PF is obstructed by ducts,
the heat radiation will be
adversely affected.
Use ducts that have a
shallow depth, to
provide a sufficient
ventilation area.
(6) Ventilation Outside the Control Panel
If the ducts cannot be made
lower, place the G3PF on a
metal base so that it is not
surrounded by the ducts.
G3PF
Be aware of airflow
Duct or other
object blocking
airflow
G3PF
Ventilation outlet
(Axial Fan)
Air inlet
G3PF
Note 1. If the air inlet or air outlet has a filter, clean the filter regularly to prevent
it from clogging to ensure an efficient flow of air.
2. Do not locate any objects around the air inlet or air outlet, otherwise the
objects may obstruct the proper ventilation of the control panel.
3. A heat exchanger, if used, should be located in front of the G3PF to
ensure the efficiency of the heat exchanger.
(7) G3PF Ambient Temperature
The rated current of the G3PF is measured at an ambient
temperature of 40°C.
(8) The G3PF uses a semiconductor to switch the load. This
causes the temperature inside the control panel to increase
due to heating resulting from the flow of electrical current
through the load. G3PF reliability can be increased by adding
a ventilation fan to the control panel to dispel this heat, thus
lowering the ambient temperature of the G3PF.
(Arrhenius's law suggests that life expectancy is doubled by
each 10°C reduction in ambient temperature.)
G3PF rated current (A)
25 A
35 A
Required number of fans per G3PF
0.4 0.54
Example: For 10 G3PF SSRs with load currents of 35 A,
0.54 × 10 = 5.40
Thus, 6 fans would be required.
Note 1. Size of fans: 92 mm2, Air volume: 0.7 m3/min, Ambient temperature
of control panel: 30°C
2. If there are other instruments that generate heat in the control panel
in addition to SSRs, more ventilation will be required.
3. Ambient temperature: The temperature that will allow the SSR to
cool by convection or other means.
G3PF
www.DataSheet4U.com
12

12 Page





SeitenGesamt 13 Seiten
PDF Download[ G3PF Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
G3PAExtremely Thin Relays IntegratedOMRON
OMRON
G3PA-VDExtremely Thin Relays IntegratedOMRON
OMRON
G3PCSSROmron
Omron
G3PC-220B-VDSSROmron
Omron
G3PFSolid State RelaysOmron
Omron

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche