Teilenummer | V600-HAR92 |
|
Beschreibung | V600 ID Systems | |
Hersteller | Omron | |
Logo | ||
Gesamt 31 Seiten Cat.No. Q104–E1–1B
www.DataSheet4U.com
V600 ID Systems
V600-HAR91/92/HAM91
CATALOG
16-bit Intelligent Flag II and 8-bit Intelligent Flag are Ideal for a Greater
Variety of Applications
Products and Main Functions
Products
OMRON’s V600-series ID
System Intelligent Flags
www.DataSheet4U.com
8-bit Intelligent Flag
8-bit Amplifier for
Read Data Output:
V600-HAR91
8-bit Amplifier with
Versatile Functions:
V600-HAM91
16-bit Intelligent Flag II
16-bit Amplifier for
Read Data Output:
V600-HAR92
Main Functions
Functions
Data reading
8 bits
16 bits
Data writing
8 bits (1 byte), block
1 bit (ON or OFF),
independent
Verification of read data with set data
Parity-check code output
Wiring saving mode
V600-HAR91
Yes
V600-HAM91
Yes
Yes
Yes
Yes
V600-HAR92
(Yes)
Yes
Yes
Yes
Ideal Combinations
The construction of an advanced line and system is possible with the Intelligent Flag or Intelligent Flag II at a mini-
mal cost. The following lists the Intelligent Flag or Intelligent Flag II that will operate the most efficiently for a given
application.
5
6 Page Production Process Control
Production process control with bit data and product inspection data.
Used as a mechanical flag to distinguish products and will set a bit to 1
when a process is completed without error.
Application 1
No. of Product Types + No. of Processes: 8 Bits or Less
Example: 16 Product Types and
4 Processes
Completion of process 2
Completion of process 1
Example: Address 0005H
www.DataSheet4U.com
Example: 4 Product Types and
6 Processes
Completion of process 3
Example: 4 types of products
and 6 processes
Completion of process 2
Example: Address 0005H
Completion of process 1
UPPER ADDRESS LOWER
DIGIT
DIGIT
Product data area:
4 bits (16 types of
products max.)
Production process control
data area:
4 bits (4 processes max.)
Product data area: Production process control
2 bits (4 types of data area:
products max.)
6 bits (6 processes max.)
SET
1. To write product data and reset product quality control data (set to 0):
Use V600-HAM91 Units and set the address of each Unit to 0005H.
2. To read product data from each process:
Use V600-HAR91 Units and set the address of each Unit to 0005H.
3. To read a Process Completion Flag from each completed process:
Use V600-HAR91 Units and set the address each Unit to 0005H.
A single V600-HAR91 can be used to read product data from each process and a Process Completion Flag
from each completed process if they are executed at the same station.
4. To write a Process Completion Flag to each completed process. (A single bit is written by the V600-HAM91 for
each process in bit set mode.):
Use V600-HAM91 Units and set the address of each Unit to 0005H.
A single V600-HAM91 can be used to read a Process Completion Flag from each completed process and write
a Process Completion Flag to each completed process if they are executed at the same station.
5. To read all data (product data and product quality control data) at the final process:
Use the V600-HAR91 and set the address to 0005H.
Process 1
Process 3
Process 4
Process 2
11
12 Page | ||
Seiten | Gesamt 31 Seiten | |
PDF Download | [ V600-HAR92 Schematic.PDF ] |
Teilenummer | Beschreibung | Hersteller |
V600-HAR91 | Intelligent Flag I/II | Omron |
V600-HAR91 | Intelligent Flag I/II | Omron |
V600-HAR91 | RFID System Applications | Omron |
V600-HAR91 | V600 ID Systems | Omron |
V600-HAR91 | Intelligent Flag I | Omron |
Teilenummer | Beschreibung | Hersteller |
CD40175BC | Hex D-Type Flip-Flop / Quad D-Type Flip-Flop. |
Fairchild Semiconductor |
KTD1146 | EPITAXIAL PLANAR NPN TRANSISTOR. |
KEC |
www.Datenblatt-PDF.com | 2020 | Kontakt | Suche |