DataSheet.es    


PDF SX05 Data sheet ( Hoja de datos )

Número de pieza SX05
Descripción (SX01 / SX05) Pressure Sensor
Fabricantes Sensym 
Logotipo Sensym Logotipo



Hay una vista previa y un enlace de descarga de SX05 (archivo pdf) en la parte inferior de esta página.


Total 10 Páginas

No Preview Available ! SX05 Hoja de datos, Descripción, Manual

SX Series
Pressure sensors
FEATURES
· 0...1 to 0...300 psi
· Absolute, differential
and gage devices
· High impedance bridge
· Low power consumption
for battery operation
www.DataSheet4U.com
APPLICATIONS
· Industrial controls
· Pneumatic controls
· Medical instrumentation
· Barometry
EQUIVALENT CIRCUIT
Vs
+
Output
-
Button sensor or "N" package
Vs
-
Output
+
TO can or DIP package
March 2004 / 052
GENERAL DESCRIPTION
The SX series of pressure sensors
provides the most cost effective
method of measuring pressures up
to 300 psi. These sensors were speci-
fically designed to be used with
non-corrosive and non-ionic media,
such as air and dry gases. Convenient
pressure ranges are available to
measure differential, gage and
absolute pressures from 0 to 1 psi
(SX01) up to 0 to 300 psi (SX7300D).
The absolute (A) devices have an in-
ternal vacuum reference and an output
voltage proportional to absolute
pressure. The differential (D) devices
allow application of pressure to either
side of the diaphragm and can be
used for gage or differential pressure
measurements.
However, 300 psi (SX7300D) can be
applied to pressure port P2 only.
Pressure port P1 is able to handle
operating pressures up to 150 psionly.
This product is packaged either in
SenSym's standard low cost chip
carrier "button" package, a plastic
ported "N" package, a metal TO can
package or a dual inline package (DIP).
All packages are designed for appli-
cations where the sensing element is
to be integral to the OEM equipment.
Scale:
1 cm
½ inch
These packages can be o-ring sealed,
epoxied, and/or clamped onto a
pressure fitting. A closed bridge 4-pin
SIP configuration is provided for elec-
trical connection to the button or "N"
package. The TO can offers a 5-pin
open bridge configuration.
Because of its high-impedance
bridge, the SX series is ideal for por-
table and low power or battery opera-
ted systems. Due to its low noise, the
SX is an excellent choice for medical
and low pressure measurements.
ELECTRICAL CONNECTION
Button sensor
GND 1
out + 2
+VS 3
out - 4
P1
Bottom view (open bridge)
GND
Out-
NC
Out+
781
62
5 43
NC
+Vs
+Vs
P2 vent hole
for gage
devices only
NC
+Vs P2
+Vs 4
1 out + out -
GND GND
out - out +
1
P1
+Vs out + 1
GND P1
4 +Vs out -
P2
+Vs
4 +Vs
vent hole
SXxxxGD2 DIP
SXxxxAD2
The polarity indicated is for pressure applied to:
SX...
: P1 (forward gage)
SX...AS/GSO : P1 (forward gage)
SX...AD2
: P1 (forward gage)
SX...GD2
: P2 (backward gage)
SX...DD4
: P2 (backward gage)
SXxxxD4 DIP
1/10
http://www.sensortechnics.com

1 page




SX05 pdf
SX Series
Pressure sensors
APPLICATION INFORMATION
General
The SX family of pressure sensors functions
as a Wheatstone bridge. When pressure is
applied to the device (see Figure I) the
resistors in the arms of the bridge change
by an amount .
www.DataSheet4U.com
Figure I. Button sensor bridge
schematic
The resulting differential output voltage V0
is easily shown to be VO= VB x . Since
the change in resistance is directly pro-
portional to pressure, V O can be written as:
VO = S x P x VB ± VOS (1)
Where: VO is the output voltage in mV
S is the sensitivity in mV/V per psi
P is the pressure in psi
VB is the bridge voltage in volts.
VOS is the offset error (the differential output
voltage when the applied pressure is zero).
The offset voltage presents little problem in
most applications, since it can easily be
corrected for in the amplifier circuitry, or
corrected digitally if a microprocessor is
used in the system.
Temperature effects
In this discussion, for simplicity of notation,
the change of a variable with temperature
will be designated with a dot (•) over the
variable. For example,
S
=
change
change
in
in
sensitivity
temperature
=
δS
δT
From equation (1), and ignoring the VOS
term, it in seen that for a given constant
pressure, the output voltage change, as a
function of temperature*, is:
••
VO = SPV B
(2)
Thus, in order for output voltage to be inde-
pendent of temperature, the voltage across
the bridge, VB, must change with tempera-
ture in the "opposite direction” from the
sensitivity change with temperature. From
the typical curves for the temperature
dependence of span (span = S x P x VB),
March 2004 / 052
it can be seen that the sensitivity change
with temperature is slightly non-linear and
can be correlated very well with an equation
of he form:
S = SO[(1 - ßTD) + ρTD2]
(3)
where TD is the temperature difference
between 25°C and the temperature of inte-
rest, SO is the sensitivity at 25°C, and beta
(ß) and rho (ρ) are correlation constants.
Fortunately, between 0°C and 70°C the
change in sensitivity with temperature is
quite linear, and excellent results can be
obtained over this temperature range by
ignoring the second-order temperature
dependent term. Operating outside the 0°C
and 70°C temperature range will require a
more rigorous mathematical approach and
the use of non-linear compensating cir-
cuitry, if accuracy of better than ±1 % is re-
quired. Because the majority of SX appli-
cations fall within the 0°C to 70°C operating
temperature range, the discussion and
circuit designs given here will ignore the
non-linear effects.
Thus:
S = SO (1 - ßTD)
(4)
Substituting equation (4) into equation (1)
and ignoring VOS, it can be shown that the
necessary bridge voltage, V B, will be of the
form:
VB = V(1B-ßOTD)=VBO [(1 - ßTD+ (ßTD)2+...)]
where V BO is the bridge voltage at 25°C.
This equation is again non-linear.
However, for the temperature range of
interest, and since ß is small (0.215%/°C
from the electrical tables), the above
expression can be approximated by:
VB=VBO [1 +ßTD]
with less than 1 % error. Thus to compen-
sate for a negative 2150 ppm/°C sensitivity
change with temperature, the bridge voltage
should increase with temperature at a rate
of +2150 ppm/°C.
The above value of bridge voltage change
will be used in the circuit discussions that
follow. That is to say, the required change
in terms of ppm/°C is:
( )V• B
VB
= +2050 ppm/°C
The bridge input resistance*, RB also
changes with temperature and is quite linear
in the temperature range of interest. The
bridge resistance has a temperature
coefficient of typically:
( )R• B = +750 ppm/°C
RB
This term enters into several compensation
circuit equations, particularly when the
bridge excitation is from a constant current
source.
To summarize, the following list indicates
how the sensor variables can be accommo-
dated
• Full-scale span from device to device.
Make the gain adjustment in the op amp
circuitry
• Temperature coefficient of span:
1) temperature compensate the bridge or
2) temperature compensate the op amp
gain
• Offsetvoltage:
Adjustment in op amp circuitry
• Offset voltage temperature coefficient:
Usually can be ignored. For more precise
design requirements, contact the factory
for information on how to compensate for
this term.
Bridge compensation circuits
Although thermistors can be used to tempe-
rature compensate the bridge (and in fact
will be required for extended temperature
operation), they are inherently non-linear,
difficult to use in volume production, and
more expensive than the circuit approaches
shown here, which use inexpensive semi-
conductor devices The circuits shown have
been designed to incorporate a minimum
number of adjustments and allow inter-
changeability of devices with little variation
from device to device. In general, equations
for the bridge voltage and its change with
temperature are given to enable the user to
modify or adjust the circuitry as required.
1. Diode string (Figure II)
For systems using 6 V supplies, this method
of compensating for the effects of span over
temperature is the lowest cost solution The
diodes are small signal silicon diodes, such
as 1N914 or 1N4148, and do not have to
be matched.
Figure II. Diode String Span
Compensation
5/10
http://www.sensortechnics.com

5 Page










PáginasTotal 10 Páginas
PDF Descargar[ Datasheet SX05.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
SX01(SX01 / SX05) Silicon Pressure SensorETC
ETC
SX01(SX01 / SX05) Pressure SensorSensym
Sensym
SX041(SX041 - SX043) Spread Spectrum Baseband ControllersAMI
AMI
SX042(SX041 - SX043) Spread Spectrum Baseband ControllersAMI
AMI

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar