DataSheet.es    


PDF CV3-2000 Data sheet ( Hoja de datos )

Número de pieza CV3-2000
Descripción Voltage Transducer
Fabricantes LEM 
Logotipo LEM Logotipo



Hay una vista previa y un enlace de descarga de CV3-2000 (archivo pdf) en la parte inferior de esta página.


Total 2 Páginas

No Preview Available ! CV3-2000 Hoja de datos, Descripción, Manual

Voltage Transducer CV 3-2000
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
VPN = 1400 V
Electrical data
VPN Primary nominal r.m.s. voltage
1400
V
V Primary voltage, measuring range
P
0 .. ± 2000
V
VS Secondary analog voltage @ VP max
10 V
K Conversion ratio
N
2000 V / 10 V
R L Load resistance
1 k
C Capacitive loading
L
5 nF
VC Supply voltage (± 5 %)
± 15
V
I Current consumption
C
32 + V / R mA
SL
Vd R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
6
kV
V R.m.s. voltage for partial discharge extinction @ 10 pC 2
e
kV
Accuracy - Dynamic performance data
X Overall accuracy @ V
G P max
V Offset voltage @ V = 0
OP
T = 25°C
A
- 40°C .. + 85°C
T = 25°C
A
- 40°C .. + 85°C
t Response time 1) @ 90 % of V
r P max
dv/dt dv/dt accurately followed
f Frequency bandwidth (- 1 dB) @ 25 % of V
PN
General data
Typ Max
± 0.2 %
± 0.6 %
± 5.0 mV
± 13.0 mV
0.4
900
DC .. 300
µs
V/µs
kHz
TA Ambient operating temperature
TS Ambient storage temperature
P Total primary power loss
R Primary resistance
1
m Mass
Standards 2)
- 40 .. + 85
- 45 .. + 90
3.1
640
560
EN 50155
°C
°C
W
k
g
Features
Closed loop (compensated) voltage
transducer
Insulated plastic case recognized
according to UL 94-V0
Patent pending.
Advantages
Excellent accuracy
Very good linearity
Low thermal drift
Low response time
High bandwidth
High immunity to external
interference
Low disturbance in common mode.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Uninterruptible Power Supplies
(UPS)
Power supplies for welding
applications
Railway overhead line voltage
measurement.
Notes : 1) With a dv/dt of 900 V/µs
2) A list of corresponding tests is available
LEM Components
030129/8
www.lem.com

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet CV3-2000.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
CV3-2000Voltage TransducerLEM
LEM

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices