DataSheet.es    


PDF XQ1005-BD Data sheet ( Hoja de datos )

Número de pieza XQ1005-BD
Descripción GaAs MMIC Voltage Controlled Oscillator
Fabricantes Mimix Broadband 
Logotipo Mimix Broadband Logotipo



Hay una vista previa y un enlace de descarga de XQ1005-BD (archivo pdf) en la parte inferior de esta página.


Total 5 Páginas

No Preview Available ! XQ1005-BD Hoja de datos, Descripción, Manual

14.2-15.2 GHz GaAs MMIC
Voltage Controlled Oscillator
April 2007 - Rev 17-Apr-07
Features
On-Chip Prescaler
+6.0 dBm Output Power
-88 dBc/Hz @ 100KHz Phase Noise
-40 dBc Harmonic Suppression
110mA @ 4.0V Bias Supply
100% On-Wafer, DC and Output Power Testing
100% Visual Inspection to MIL-STD-883
Method 2010
Q1005-BD
Chip Device Layout
General Description
Mimix Broadband's 14.2-15.2 GHz GaAs HBT VCO is a fully
integrated oscillator MMIC with on-chip frequency doubler and
divide-by-8 prescaler (w.r.t RFout).This design is based on a
cross coupled differential pair with on-chip tuning diode and
resonator.The use of a high-Q resonator structure and
integrated varactor diodes results in optimum phase-noise
performance, whilst the integration of frequency doubler and
prescaler reduce application complexity and time-to-market.
This MMIC uses Mimix Broadband's 2 um GaAs HBT device
model technology to ensure low flicker (1/f ) noise and high
www.DataSheet4U.comreliability. The chip has surface passivation to protect and
provide a rugged part with backside via holes and gold
metallization to allow either a conductive epoxy or eutectic
solder die attach process.This device is well suited for
Millimeter-wave Point-to-Point Radio, LMDS, SATCOM and VSAT
applications.
Absolute Maximum Ratings
Supply Voltage (Vcc1,2,3)
+5.0 VDC
Supply Voltage (Vtune)
+7.0 VDC
Supply Current (Icc1,2,3)
150 mA
Supply Current (Itune)
1 mA
Storage Temperature (Tstg)
Operating Temperature (Ta)
Junction Temperature (Tjn)
-65 to +165 OC
-55 to MTTF Table1
MTTF Table1
(1) Junction temperature affects a device's MTTF. It is
recommended to keep channel temperature as low as
possible for maximum life.
o
Electrical Characteristics (Ambient Temperature T = 25 C)
Parameter
Units Min. Typ. Max.
Frequency Range (f )
GHz 14.2 - 15.2
Prescaler Frequency Range (f )
GHz 1.775 - 1.900
Fundamental Output Power (Pout)
dBm - +6.0 -
Prescaler Output Power (Pout)
dBm - +2.0 -
SSB Phase Noise @ 100 kHz Offset
dBc/Hz
-
-88.0
-
SSB Phase Noise @ 1 MHz Offset
dBc/Hz
-
-113.0
-
Subharmonic Suppression
dBc - -40.0 -
2nd Harmonic Suppression
dBc - -48.0 -
3rd Harmonic Suppression
dBc - -42.0 -
Frequency Pushing (Vcc)
MHz/Volt
-
40.0
-
Supply Voltage (Vcc)
VDC - +4.0 -
Frequency Tuning Voltage (Vtune)
VDC +1.0 - +6.0
Supply Current (Icc) (Vcc=4.0V Typical)
mA - 110 130
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 1 of 5
Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc.
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept
their obligation to be compliant with U.S. Export Laws.

1 page




XQ1005-BD pdf
14.2-15.2 GHz GaAs MMIC
Voltage Controlled Oscillator
April 2007 - Rev 17-Apr-07
Q1005-BD
Handling and Assembly Information
CAUTION! - Mimix Broadband MMIC Products contain gallium arsenide (GaAs) which can be hazardous to the
human body and the environment. For safety, observe the following procedures:
Do not ingest.
Do not alter the form of this product into a gas, powder, or liquid through burning, crushing, or chemical
processing as these by-products are dangerous to the human body if inhaled, ingested, or swallowed.
Observe government laws and company regulations when discarding this product.This product must be
discarded in accordance with methods specified by applicable hazardous waste procedures.
Life Support Policy - Mimix Broadband's products are not authorized for use as critical components in life support
devices or systems without the express written approval of the President and General Counsel of Mimix
Broadband. As used herein: (1) Life support devices or systems are devices or systems which, (a) are intended for
surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in
accordance with instructions for use provided in the labeling, can be reasonably expected to result in a
significant injury to the user. (2) A critical component is any component of a life support device or system whose
failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
ESD - Gallium Arsenide (GaAs) devices are susceptible to electrostatic and mechanical damage. Die are supplied
in antistatic containers, which should be opened in cleanroom conditions at an appropriately grounded anti-
static workstation. Devices need careful handling using correctly designed collets, vacuum pickups or, with care,
sharp tweezers.
Die Attachment - GaAs Products from Mimix Broadband are 0.100 mm (0.004") thick and have vias through to the
backside to enable grounding to the circuit. Microstrip substrates should be brought as close to the die as
possible.The mounting surface should be clean and flat. If using conductive epoxy, recommended epoxies are Tanaka
TS3332LD, Die Mat DM6030HK or DM6030HK-Pt cured in a nitrogen atmosphere per manufacturer's cure schedule.
Apply epoxy sparingly to avoid getting any on to the top surface of the die. An epoxy fillet should be visible around the
total die periphery. For additional information please see the Mimix "Epoxy Specifications for Bare Die" application note.
If eutectic mounting is preferred, then a fluxless gold-tin (AuSn) preform, approximately 0.0012 thick, placed between
the die and the attachment surface should be used. A die bonder that utilizes a heated collet and provides scrubbing
action to ensure total wetting to prevent void formation in a nitrogen atmosphere is recommended.The gold-tin
eutectic (80% Au 20% Sn) has a melting point of approximately 280 ºC (Note: Gold Germanium should be avoided).The
work station temperature should be 310 ºC +/- 10 ºC. Exposure to these extreme temperatures should be kept to
minimum.The collet should be heated, and the die pre-heated to avoid excessive thermal shock. Avoidance of air
bridges and force impact are critical during placement.
Wire Bonding - Windows in the surface passivation above the bond pads are provided to allow wire bonding to
the die's gold bond pads.The recommended wire bonding procedure uses 0.076 mm x 0.013 mm (0.003" x
0.0005") 99.99% pure gold ribbon with 0.5-2% elongation to minimize RF port bond inductance. Gold 0.025 mm
(0.001") diameter wedge or ball bonds are acceptable for DC Bias connections. Aluminum wire should be
avoided.Thermo-compression bonding is recommended though thermosonic bonding may be used providing
the ultrasonic content of the bond is minimized. Bond force, time and ultrasonics are all critical parameters.
Bonds should be made from the bond pads on the die to the package or substrate. All bonds should be as short
as possible.
Part Number for Ordering
XQ1005-BD-000V
XQ1005-BD-EV1
Description
Where “V” is RoHS compliant die packed in vacuum release gel paks
XQ1005 die evaluation module
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 5 of 5
Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc.
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept
their obligation to be compliant with U.S. Export Laws.

5 Page










PáginasTotal 5 Páginas
PDF Descargar[ Datasheet XQ1005-BD.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
XQ1005-BDGaAs MMIC Voltage Controlled OscillatorMimix Broadband
Mimix Broadband

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar