DataSheet.es    


PDF L36SA05010 Data sheet ( Hoja de datos )

Número de pieza L36SA05010
Descripción DC/DC Power Module
Fabricantes Delta Electronics 
Logotipo Delta Electronics Logotipo



Hay una vista previa y un enlace de descarga de L36SA05010 (archivo pdf) en la parte inferior de esta página.


Total 13 Páginas

No Preview Available ! L36SA05010 Hoja de datos, Descripción, Manual

Delphi Series L36SA, 2 x 1.6, 50W Family
DC/DC Power Module: 18~75V in, 5.0V/10A outwww.DataSheet4U.com
The Delphi Series L36SA, 2” x 1.6”, 18~75V input, single output,
isolated DC/DC converter is the latest offering from a world leader in
power systems technology and manufacturing - Delta Electronics,
Inc. This L36SA series provides up to 50 watts of power or 15A of
output current (3.3V) in an industry standard 2 x 1.6 form factor and
pinout. The Delphi L36SA series operates from a wide 18~75V (4:1)
input voltages. With creative design technology and optimization of
component placement, these converters possess outstanding
electrical and thermal performances, as well as extremely high
reliability under highly stressful operating conditions. All models are
fully protected from abnormal input/output voltage, current, and
temperature conditions. The Delphi Series converters meet all
safety requirements with basic insulation. An optional heat spreader
is available for extended operation.
FEATURES
High Efficiency: 89% @ 5.0V/10A
Size: 49.6mm x 39.4mm x 8.9mm
(1.95”x1.55”x0.35”)
Industry standard pin out
Fixed frequency operation
Input UVLO, OTP, Output OCP, OVP,
(auto recovery)
Monotonic startup into normal and
pre-biased loads
2250V isolation and basic insulation
No minimum load required
4:1 Input voltage range
ISO 9001, TL 9000, ISO 14001, QS 9000,
OHSAS 18001 certified manufacturing
facility
UL/cUL 60950 (US & Canada)
Recognized, and TUV (EN60950)
certified.
CE mark meets 73/23/EEC and
93/68/EEC directives
OPTIONS
Positive On/Off logic
Sense
Negative trim
Heat spreader
APPLICATIONS
Telecom/Datacom
Wireless Networks
Optical Network Equipment
Server and Data Storage
Industrial/Testing Equipment
DATASHEET
DS_L36SA05010_02142007

1 page




L36SA05010 pdf
ELECTRICAL CHARACTERISTICS CURVES
Figure 8: Output voltage response to step-change in load
current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap:
10µF, tantalum capacitor and 1µF ceramic capacitor. Top Trace:
Vout (100mV/div,500us/div), Bottom Trace: I out (5A/div).
Scope measurement should be made using a BNC cable
(length shorter than 20 inches). Position the load between 51
mm to 76 mm (2 inches to 3 inches) from the module..
Figure 9: Output voltage response to step-change in load
current (75%-50%-75% of Io, max; di/dt = 2.0A/µs). Load cap:
330µF, 35mESR solid electrolytic capacitor and 1µF ceramic
capacitor. Top Trace: Vout (100mV/div, 500us/div), Bottom
Trace: I out (5A/div). Scope measurement should be made
using a BNC cable (length shorter than 20 inches). Position the
load between 51 mm to 76 mm (2 inches to 3 inches) from the
module.
Figure 10: Test set-up diagram showing measurement points
for Input Terminal Ripple Current and Input Reflected Ripple
Current.
Note: Measured input reflected-ripple current with a simulated
source Inductance (LTEST) of 12 µH. Capacitor Cs offset
possible battery impedance. Measure current as shown above
DS_L36SA05010_02142007
5

5 Page





L36SA05010 arduino
THERMAL CONSIDERATIONS
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).
Thermal Derating
Heat can be removed by increasing airflow over the
module. To enhance system reliability, the power module
should always be operated below the maximum
operating temperature. If the temperature exceeds the
maximum module temperature, reliability of the unit may
be affected.
THERMAL CURVES
FACING PWB
PWB
MODULE
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
AIR FLOW
50.8 (2.0”)
12.7 (0.5”)
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 20: Wind tunnel test setup
Figure 21: Temperature measurement location
The allowed maximum hot spot temperature is defined at 130
Output Current (A)
11
L36SA05010(standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin = 48V (Either Orientation)
10
9
8
Natural
Convection
7
100LFM
6 200LFM
300LFM
5
4
3
2
1
0
40 45 50 55 60 65 70 75 80 85
Ambient Temperature ()
Figure 22: Output current vs. ambient temperature and air
velocity @ Vin=48V (Either Orientation)
DS_L36SA05010_02142007
11

11 Page







PáginasTotal 13 Páginas
PDF Descargar[ Datasheet L36SA05010.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
L36SA05010DC/DC Power ModuleDelta Electronics
Delta Electronics

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar