DataSheet.es    


PDF RUE Data sheet ( Hoja de datos )

Número de pieza RUE
Descripción RUE Selection Guide
Fabricantes Raychem 
Logotipo Raychem Logotipo



Hay una vista previa y un enlace de descarga de RUE (archivo pdf) en la parte inferior de esta página.


Total 11 Páginas

No Preview Available ! RUE Hoja de datos, Descripción, Manual

www.DataSheet4U.com
RUE Selection Guide
and Product Data
This section has two parts:
• A Selection Guide that walks you through the process of
selecting the correct RUE device for a circuit.
• Product Data that outlines electrical characteristics,
physical characteristics, agency recognitions, environmental
specifications, component layouts, tape and reel specifications,
and ordering information for RUE devices.
RUE Selection Guide
Follow these seven steps to select a PolySwitch RUE device for
a circuit:
1. Define the operating parameters for the circuit.
These include:
• Maximum ambient operating temperature
• Normal operating current
• Maximum operating voltage (RUE is 30 V maximum)
• Maximum interrupt current
2. Select the RUE device that accommodates the circuit’s maximum
ambient operating temperature and normal operating current.
3. Compare the RUE device’s maximum operating voltage and maxi-
mum interrupt current with the circuit’s to be sure the circuit does not
exceed the device ratings.
4. Check the RUE device’s time-to-trip to be sure it will protect the
circuit.
5. Verify that the circuit’s ambient operating temperatures are within the
RUE device’s operating temperature range.
6. Verify that the RUE device’s dimensions fit the application’s space
considerations.
7. Independently evaluate and test the suitability and performance
of the RUE device in the application.
4
®
® TUV Rheinland
Raychem Circuit Protection Devices
RUE Devices 141

1 page




RUE pdf
5. Verify ambient operating conditions.
RUE
Radial Leaded
Ensure that your application’s minimum and maximum ambient
temperatures are within the operating temperature range of –40°C
and 85°C.
Maximum device surface temperature in the tripped state is 125°C.
6. Verify the RUE device’s dimensions.
Using dimensions from the table below, compare the dimensions of the
RUE device you selected with the application’s space considerations.
Product dimensions (millimeters/inches)
Part
number
RUE090
RUE110
RUE135
RUE160
RUE185
RUE250
RUE300
RUE400
RUE500
RUE600
RUE700
RUE800
RUE900
A
max.
7.4 (0.29)
7.4 (0.29)
8.9 (0.35)
8.9 (0.35)
10.2 (0.40)
11.4 (0.45)
11.4 (0.45)
14.0 (0.55)
14.0 (0.55)
16.5 (0.65)
19.1 (0.75)
21.6 (0.85)
24.1 (0.95)
B
max.
12.2 (0.48)
14.2 (0.56)
13.5 (0.53)
15.2 (0.60)
15.7 (0.62)
18.3 (0.72)
17.3 (0.68)
20.1 (0.79)
24.9 (0.98)
24.9 (0.98)
26.7 (1.05)
29.2 (1.15)
29.7 (1.17)
C
typ.
5.1 (0.20)
5.1 (0.20)
5.1 (0.20)
5.1 (0.20)
5.1 (0.20)
5.1 (0.20)
5.1 (0.20)
5.1 (0.20)
10.2 (0.40)
10.2 (0.40)
10.2 (0.40)
10.2 (0.40)
10.2 (0.40)
D
min.
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
7.6 (0.30)
E
max.
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
3.0 (0.12)
F
typ.
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
1.2 (0.05)
1.2 (0.05)
1.2 (0.05)
1.2 (0.05)
1.2 (0.05)
1.2 (0.05)
1.2 (0.05)
4
Lead size
RUE090–RUE250
Ø 0.51
(0.020)
24 AWG
RUE300–RUE900 Ø 0.81
(0.032)
20 AWG
* Straight leads are available
** Kinked leads are available
RUE090–RUE250*
A
E
Marking
B
D
C
CL CL
F
CL CL
RUE300–RUE900**
A
E
Marking
B
D
C
CL CL
F
CL CL
Raychem Circuit Protection Devices
RUE Devices 145

5 Page





RUE arduino
Part marking system
V 30
U135
NJ2K
Example
RUE
Radial Leaded
V - 30
U
Voltage rating
Raychem symbol
Part ID
Product family (RUE)
Lot number/Date code (may be on the back)
Part
description
RUE090
RUE110
RUE135
RUE160
RUE185
RUE250
RUE300
RUE400
RUE500
RUE600
RUE700
RUE800
RUE900
Part
ID
090
110
135
160
185
250
300
400
500
600
700
800
900
4
Raychem Circuit Protection Devices
WARNING:
• Operation beyond maximum ratings or improper use may result in
device damage and possible electrical arcing and flame.
• These devices are intended for protection against occasional over-
current or overtemperature fault conditions, and should not be used
when repeated fault conditions are anticipated.
• Operation in circuits with inductive spikes can generate voltages
above the rated voltage of the devices and should be evaluated for
suitability of use.
RUE Devices 151

11 Page







PáginasTotal 11 Páginas
PDF Descargar[ Datasheet RUE.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
RU-050505ECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power
RU-050909ECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power
RU-051.81.8ECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power
RU-051212ECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar