Datenblatt-pdf.com


IB235 Schematic ( PDF Datasheet ) - HOBART

Teilenummer IB235
Beschreibung (IB235 / IB290) GAS Infrared Booster
Hersteller HOBART
Logo HOBART Logo 




Gesamt 2 Seiten
IB235 Datasheet, Funktion
www.DataSheet4U.com
FOOD EQUIPMENT
Item # ________________________________
Quantity _______________________________
C.S.I. Section 11400
IB235 AND IB290
GAS INFRARED BOOSTER
STANDARD FEATURES
s Stainless steel frame.
s Stainless steel legs and adjustable feet.
s Stainless steel 17 gallon tank.
s Stainless steel finned heat exchanger coil.
s Woven ceramic fiber infrared burner.
s 235,000 or 290,000 BTU/hr input.
s Two indicator lights - power on and heat on.
s Two high limit controls, automatic and manual
resets.
s 12 H.P. recirculating pump motor.
s 120/60/1 voltage.
s Temperature/pressure relief valve.
s Drain valve.
s Solid state thermostat.
s Blocked vent switch.
s Air flow switch.
s Vent fan control.
s Connections for external air pressure switch.
SPECIFICATIONS
Hobart Model IB _____ which provides _____ GPH
(_____ GPM) of 180°F (82°C) rinse water when
supplied with ______ BTU/Hr. of natural or propane
gas. Shall have a stainless steel frame, legs, and
adjustable feet with a stainless steel 17 gallon tank
which meets the requirements of the ASME Boiler
and Pressure Vessel Code. Equipped with a woven
ceramic fiber infrared burner and stainless steel
finned heat exchanger coil. Shall be 120 volts,
60 cycle, single phase and include two indicator
lights, automatic and manual reset high limit controls,
drain valve, air flow switch, temperature/pressure
relief valve, and vent fan control. Listed by NSF
International and Certified by AGA and CGA. Shall
have the capability to comply with the National Fuel
Gas Code, NFPA 54.
Net Weight: 420 lbs.
Shipping Weight: 490 lbs.
GAS OPTIONS
(must choose one)
DataSheet4U.com
VENTILATION
u Natural
u Propane
Before installing any method of venting, contact the
local code authority or your gas supplier to make
sure that the final installation will be acceptable to
POWER CONTROL OPTIONS
(must choose one)
u ON/OFF power switch on booster.
u Integrated power control (with new Hobart
the authorities who have jurisdiction. The proper
method of venting is explained in detail in the
National Fuel Gas Code. Also see our Installation
Manual.
dishmachine only).
Details and Dimensions on Reverse Side.
ACCESSORIES
u Pressure regulating valve.
u Shock arrestor, pressure regulating valve,
pressure gauge kit.
u Inlet temperature gauge.
DataShee
BOOSTER SIZING CHART
Gas
Input
Recovery Rate @ 180°F (82.2°C)
Inlet Water Temperature
MBH
110° 120° 130° 140° 150°
235 GPH
Natural or Propane GPM
322
5.37
376
6.27
451
7.52
564 752
9.4 12.54
290 GPH 398 464 557 696 928
Natural GPM 6.63 7.74 9.28 11.6 15.47
280 GPH 384 448 538 672 896
Propane GPM 6.40 7.47 8.96 11.2 14.94
DataSheet4U.cRoamtings shown are for elevations up to 2,000 feet. For elevations over 2,000
feet, reduce ratings at the rate of 4% for each 1,000 feet above sea level.
DataSheet4 U .com
701 S Ridge Avenue, Troy, OH 45374 • 937-332-3000 • 1-800-960-1190





SeitenGesamt 2 Seiten
PDF Download[ IB235 Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
IB235(IB235 / IB290) GAS Infrared BoosterHOBART
HOBART
IB235Bosch Replacement TegulatorTranspo
Transpo

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche