Datenblatt-pdf.com


V23062 Schematic ( PDF Datasheet ) - Tyco

Teilenummer V23062
Beschreibung Cradle Relay
Hersteller Tyco
Logo Tyco Logo 




Gesamt 18 Seiten
V23062 Datasheet, Funktion
AXICOM
Telecom-, Signal and RF Relays
Cradle Relay S V23054 / V23062
108-98014 • Nov. 07 • Rev. C • ECOC: JM10






V23062 Datasheet, Funktion
AXICOM
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
108-98014 Rev. C
Coil Data and operating range
Nominal voltage
Typical nominal power consumption, at 20 °C
Class of the operative range
acc to EN 61810-1 / IEC 61810-1 and VDE 0435 Part 201
Operating voltage (according to the coil type)
from 6 Vdc to 220 Vdc
1W
2
max. 92% of the nominal voltage
Terminals:
Coil with 1 winding
Start 4 End 1
Coil with 2 windings (upon request)
Start 3 End 2 for winding I
Start 4 End 1 for winding II
The minimum voltage UI depends on the contact set and the ambient temperature, the maximum voltage UII
only depends on the ambient temperature.
Between minimum voltage UI tamb and operating voltage U a safety margin of approx. 20% is recommended.
UI tamb (1.2)
< UI UII tamb
UI tamb = UI · U20 °C · kI tamb
UII tamb = UIl 20 °C · kII tamb
tamb = Ambient temperature
U = Operating voltage
UI tamb = Minimum voltage at ambient temperature, tamb
UII tamb = Maximum voltage at ambient temperature, tamb
kI and kII = Factors
Note: Instructions for impulse operation
see data sheet cradle relay N
Ambient temperature tamb [°C]
All specifications subject to change. Consult Tyco Electronics for latest specifications.
6 of 18

6 Page









V23062 pdf, datenblatt
AXICOM
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
108-98014 Rev. C
Instructions for Impulse Operation
The maximum voltage stated in the table (page 6) can be increased for impulse operation as follows:
UII Impuls =
UII tamb =
q=
UII tamb . q
Maximum continuous voltage at ambient temperature t amb
Factor
The impulse voltage must not exceed 80% of the test voltage (winding/frame or winding/winding) or not to exceed the
max. voltage as listed in the table (page 6) by no more than 2.3 told.
Ift ED 3 s then q
=
Ift ED
t2
If tED
=
=
>
Pulse width
Cycle time
3 s the value of q must be obtained from the nomograph (next page).
Examples of various periodic pulse trains (energizing side)
1. Periodic recurrence of one energizing pulse
2. Periodic recurrence of two unequal energizing pulses
tED =
tI + tII =
tI + tII
Pulse widths within one cycle
All specifications subject to change. Consult Tyco Electronics for latest specifications.
12 of 18

12 Page





SeitenGesamt 18 Seiten
PDF Download[ V23062 Schematic.PDF ]

Link teilen




Besondere Datenblatt

TeilenummerBeschreibungHersteller
V23062Cradle RelayTyco
Tyco

TeilenummerBeschreibungHersteller
CD40175BC

Hex D-Type Flip-Flop / Quad D-Type Flip-Flop.

Fairchild Semiconductor
Fairchild Semiconductor
KTD1146

EPITAXIAL PLANAR NPN TRANSISTOR.

KEC
KEC


www.Datenblatt-PDF.com       |      2020       |      Kontakt     |      Suche